Part 5: Review on Replacement of MR-J3-DU_ with MR-J4-DU_
(2) Selection example of crimp terminals
The following shows the selection example of crimp terminals for terminal blocks of the drive unit and
converter unit when you use wires mentioned in (1) in this section.
Symbol
Crimp terminal
(Note 2)
a
FVD5.5-10
b
FVD22-10
c
R38-10
(Note 1)
d
R60-10
(Note 1)
e
FVD22-8
f
R38-8
(Note 1)
g
FVD2-4
Note 1. Coat the crimping part with an insulation tube.
2. Installation of a crimp terminal may be impossible depending on the size, so make sure to use the
recommended crimp terminal or one equivalent to it.
Drive unit/converter unit-side crimp terminal
Applicable tool
Body
Head
YNT-1210S
YF-1
YNE-38
E-4
YPT-60-21
YF-1
YET-60-1
E-4
YPT-60-21
YF-1
YET-60-1
E-4
YF-1
YNE-38
E-4
YPT-60-21
YF-1
YET-60-1
E-4
YNT-1614
5 - 54
Manufacturer
Dice
DH-123
DH-113
TD-124
TD-112
TD-125
JST
TD-113
(J.S.T. Mfg. Co., Ltd.)
DH-123
DH-113
TD-124
TD-112