Mitsubishi Electric MELSERVO-J3 Series Handbook page 97

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

Part 2: Review on Replacement of MR-J3-_A_ with MR-J4-_A_
(2) [Pr. PC16 Electromagnetic brake sequence output]
MR-J3-_A_ and MR-J4-_A_ have different initial values for [Pr.PC16] (MR-J3-_A_: 100 ms, MR-J4-_A_:
0 ms). When MBR (Electromagnetic brake interlock) is assigned for [Pr. PD23] to [Pr. PD26] and [Pr.
PD28], refer to the MR-J4-_A_ Servo Amplifier Instruction Manual and then set [Pr.PC16].
No./symbol/
Setting
name
digit
PC16
MBR
Electromagnetic
brake sequence
output
(3) Input signal filter selection (_ _ _ x) of [Pr. PD29 Input filter setting]
MR-J3-_A_ and MR-J4-_A_ have different initial values for the input signal filter selection.
No./symbol/
Setting
name
digit
PD29
Select a filter for the input signal.
*DIF
_ _ _ x
Input filter
setting
_ _ x _
_ x _ _
x _ _ _
Set the delay time between MBR (Electromagnetic brake interlock) and the
base drive circuit is shut-off.
Setting range: 0 to 1000
Input signal filter selection
If external input signal causes chattering due to noise, etc., input filter is used to
suppress it.
Setting value
MR-J4-_A_
0
None
1
0.888 [ms]
2
1.777 [ms]
3
2.666 [ms]
4
3.555 [ms] (Initial value)
RES (Reset) dedicated filter selection
0: Disabled
1: Enabled (50 [ms])
CR (Clear) dedicated filter selection
0: Disabled
1: Enabled (50 [ms])
For manufacturer setting
Function
Function
MR-J3-_A_
None
1.777 [ms]
3.555 [ms] (Initial value)
5.333 [ms]
2 - 64
Control mode
Initial
value
(: Enabled)
[unit]
P
S
T
0
[ms]
Control mode
Initial
(:Enabled)
value
[unit]
P
S
T
4h
0h
0h
0h

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents