7.
In "Level trigger condition setting", select any of the following.
Setting
value
0: Disable
Select when a stop condition of logging is not set. (Logging can be stopped at any timing.)
1: Above
2: Below
Select a value to set a stop
condition of logging.
(Logging stops when the
value in the buffer memory
satisfies the set condition.)
3: Pass
Through
102
Description
Logging stops when the status of "Trigger data < Trigger setting value" turns to that of
"Trigger data > Trigger setting value"
Trigger data
Trigger
setting value
Logging stops when the status of "Trigger data > Trigger setting value" turns to that of
"Trigger data < Trigger setting value"
Trigger data
Trigger
setting value
Logging stops when the trigger data passes the trigger setting value. (Either of the following
(1) or (2))
(1)
When the status of "Trigger data < Trigger setting value" turns to that of "Trigger data
> Trigger setting value"
(2)
When the status of "Trigger data > Trigger setting value" turns to that of "Trigger data
< Trigger setting value"
Trigger data
Trigger
setting value
Example When the trigger
setting value is 70
Trigger data
Trigger
occurrence
Time
Example When the trigger
setting value is 70
Trigger data
Trigger
occurrence
Time
Trigger
occurrence
(1)
64
66
67
69
70
Trigger occurs
71
72
at this point
74
...
74
72
71
70
Trigger occurs
69
at this point
67
66
64
...
Trigger
occurrence
(2)
Time