Download Print this page

Brasiltec SC1-3003 Technical Manual page 73

Ac servo system

Advertisement

H:Parameter reserved
Initial value:n. 00 00
( H
Control mode:Origin mode
Unit:~
Setting range:~
Modify effective time:"●"can be modified at any time, and will take effect by power off and
restart.
Parameter function:The same as P5-10.L
◎P5-21
L:/COIN Positioning finish
H:/V-CMP Synchronous speed detection
Initial value:n. 00 01
( H
Control mode:~
Unit:~
Setting range:
Modify effective time:"●"can be modified at any time, and will take effect by power off and
restart.
Parameter function:
L:00: No output to terminal
02: Output positive signal from SO2 terminal
03: Output positive signal from SO3 terminal
81: Output reverse signal from SO1 terminal
83: Output reverse signal from SO3 terminal
H:The same as P5-21.L
◎P5-22
L:/TGON Rotation detection H:/S-RDY Ready
Initial value:n. 00 00
( H
Control mode:~
Unit:~
Setting range:~
Modify effective time:"●"can be modified at any time, and will take effect by power off and
restart.
Parameter function:The same as P5-21.L
◎P5-23
L:/CLT Torque
L)
L)
L)
H:/VLT Speed limit detection
73
01: Output positive signal from SO1 terminal
03: Output positive signal from SO3 terminal
04: Output positive signal from SO4 terminal
82: Output reverse signal from SO2 terminal
84: Output reverse signal from SO4 terminal
0X0514
0X0515
0X0516

Advertisement

loading

This manual is also suitable for:

Sc1-3010Sc1-3011