P5-03
Torque limit
P4-02
P4-03
P0-07
P4-04
P4-05
P5-13.L
P5-13.H
Soft start
P3-05
P3-06
Filter
P3-07
P3-08
6.5.1Control method selection
Parameter
Setting value
P0-01
4
6.5.2 Rated speed corresponds to analog
◎P3-00
corresponds to
Initial value:1000
Control mode:4
Unit:0.01V
Setting range:150~3000
Modify effective time:"○"can modify when servo OFF,and take effective by servo ON
Parameter function:Set the speed command voltage (V-REF) according to the servo motor
operation at the rated speed
Eg:P3-00=500,when the analog input voltage is 5.00V, the motor runs at the rated speed;
P3-00=800,when the analog input voltage is 8.00V, the motor runs at the rated speed.
6.5.3 Automatic adjustment of speed command offset (F1-00)
When the analog voltage speed mode is used,even the command voltage is 0V, the motor still
will rotate at a small speed. This micro-motion occurs when the command voltage of the suprior
Synchronous speed signal detection
width/V-CMP
Forward torque limit
Reverse torque limit
T-REF distribution
Forward external torque limit
Reverse external torque limit
Forward external torque limit/P-CL
Reverse external torque limit/N-CL
Soft start acceleration
Soft start deceleration
Speed command filter time parameter
Speed feedback filter time parameter
Meaning
Speed (analog)
Rated speed
analog
Modify
Servo OFF
35
6.5.6
6.5.7
6.5.7
6.5.7
6.5.7
6.5.7
6.5.7
6.5.7
6.5.8
6.5.8
6.5.9
6.5.9
Take effect
Immediate