Download Print this page

Brasiltec SC1-3003 Technical Manual page 70

Ac servo system

Advertisement

2) When the servo is turned OFF, the set time is exceeded of P5-08 value.
In the "P5-07", even if the speed is set above the MAX speed, the actual speed value is only the
MAX speed (P3-09).
◎P5-09
Parameter reserved
◎P5-10
H:/S-ON L:Input signal distribution mode
Initial value:n. 01 01
( H
Control mode:All
Unit:~
Setting range:~
Modify effective time:"●"can be modified at any time, and will take effect by power off and
restart.
Parameter function:
H:00:Set the signal to always be invalid
02:Input positive signal from SI2 terminal
04:Input positive signal from SI4 terminal
06:Input positive signal from SI6 terminal
08:Input positive signal from SI8 terminal
80:Set the signal to always be active
82:Input reverse signal from SI2
84:Input reverse signal from SI4
86:Input reverse signal from SI6
L:00:External input is completely based on factory settings,the setting of P5-10.H~P5-19.H is
invalid
01:External input signal can be set freely,the setting of P5-10.H~P5-19.H is valid.
◎P5-11
L:/P-CON Proportional action instruction
H:/P-OT Prohibit forward drive
Initial value:n. 03 02
( H
Control mode:All
Unit:~
Setting range:
Modify effective time:"●"can be modified at any time, and will take effect by power off and
restart.
Parameter function:The same as P5-10.H
L: P-CON Proportional action instruction
The signal is valid: it is operated in P (proportional) control mode (the jog caused by the drift of
the speed input command can be reduced, but at the same time the rigidity of the servo motor will
decrease, and the output torque will be small when stopped)
Invalid signal: run in PI (proportional integral) control mode
L)
01:Input positive signal from SI1 terminal
L)
70
03:Input positive signal from SI3 terminal
05:Input positive signal from SI5 terminal
07:Input positive signal from SI7 terminal
81:Input reverse signal from SI1 terminal
83:Input reverse signal from SI3
85:Input reverse signal from SI5
87:Input reverse signal from SI7
0X0509
0X050a
0X050b

Advertisement

loading

This manual is also suitable for:

Sc1-3010Sc1-3011