◎P3-00
Rated speed corresponds to analog
Initial value:1000
Control mode:4
Unit:0.01V
Setting range:150~3000
Modify effective time:"○"can modify when servo OFF,and take effective by servo ON
Parameter function:Set the speed command voltage (V-REF) required to operate the servo
motor at the rated speed
Eg:P3-00=500 means the motor is running at rated speed when the analog input voltage is 5.00V.
P3-00=800,means when the analog input voltage is 8.00V, the motor runs at the rated speed.
◎P3-01
Internal speed setting 1
Initial value:0
Control mode:Speed control (internal speed setting selection)
Unit:r/m(rpm)
Setting range:-3000~3000
Modify effective time:"√"can modify at any time,will take effect immediately.
Parameter function:set value of speed 1
◎P3-02
Internal speed setting 2
Initial value:0
Control mode:Speed control (internal speed setting selection)
Unit:r/m(rpm)
Setting range:-3000~3000
Modify effective time:"√"can modify at any time,will take effect immediately.
Parameter function:set value of speed 2
◎P3-03
Internal speed setting 3
Initial value:0
Control mode:Speed control (internal speed setting selection)
Unit:r/m(rpm)
Setting range:-3000~3000
Modify effective time:"√"can modify at any time,will take effect immediately.
Parameter function:set value of speed 3
◎P3-04
JOG speed
Initial value:100
Control mode:JOG main mode:2
Unit:r/m(rpm)
Setting range:0~10000
Modify effective time:"√"can modify at any time,will take effect immediately.