Download Print this page

Brasiltec SC1-3003 Technical Manual page 49

Ac servo system

Advertisement

acceleration and
deceleration time
P2-36
Third stage pulse
number
P2-37
Third stage pulse
number
P2-38
Third stage speed
P2-39
Third stage waiting
P2-40
Third stage
acceleration and
deceleration time
P2-41
Forth stage pulse
number
P2-42
Forth stage pulse
number
P2-43
Forth stage speed
P2-44
Forth stage waiting
P2-45
Forth stage
acceleration and
deceleration time
P2-46
Position S type
acceleration and
deceleration time
P3-XX
Paramete
Function
r code
P3-00
Rated speed
corresponds to
analog
P3-01
Internal speed 1
P3-02
Internal speed 2
P3-03
Internal speed 3
P3-04
JOG speed
P3-05
Soft start
acceleration time
P3-06
Soft start
deceleration time
P3-07
Speed command
filter time
parameter
1
10000
0.1rpm
ms
time
ms
1
10000
0.1rpm
ms
time
ms
ms
Speed parameter Modbus address:0300~03FF
Unit
0.01V
rpm
rpm
rpm
rpm
1ms
1ms
0.01ms
49
0
-9999~+9999
0
0
0
0
-9999~+9999
0
-9999~+9999
0
0
0
0
-9999~+9999
0
-9999~+9999
Factory
Setting range
default
1000
150~3000
100
-5000~+5000
200
-5000~+5000
300
-5000~+5000
100
0~1000
0
0~65535
0
0~65535
0
0~65535
Effective time

Advertisement

loading

This manual is also suitable for:

Sc1-3010Sc1-3011