4.4 Brief description of code display
code
4.5 Restore factory setting
Restore all user parameters to factory settings, including P0-11 motor code
Please confirm the parameters before reseting, or it will not be able to recover.
When need to restore the factory settings?
Alarm EN-02, parameter damage
An abnormal operation caused by setting parameters during debugging
There is a command send to motor,but it does not run, no alarm, check if P3-09
value is 0, if it is, then restore the factory setting.
Steps:
1. Turn off the enable signal first. ( External enable: Please disconnect the external signal;
Internal power-on enable: set P0-01 to n.0101 and then power off and restart)
2. Enter F4-00
(Refer to e in section 4.2)
3. Check the motor parameters (take the drive SC1-3010/AMS80-02430Z as an
example)
a)
Check motor code power code F0-00 :display 750 means 750W
b)
Check motor model code F0-24: shows 02430 indicates 2.4N·M, 3000 rpm
c)
Check input voltage level and flange F0-25:display 2080 indicates 220V, 80
flange
If the alarm is EN-02, also need current check, please refer to section 4.6
Display content
In standby mode
Servo OFF status (The motor is powered off)
Running
Servo enable(The motor is powered on)
Prohibition of forward rotation
P-OT OFF status. Please refer to "Overtravel Setting".
Prohibition of reverse rotation
N-OT OFF status. Please refer to "Overtravel setting"