Ventilation And Cooling; Replacing The Hip Blowers (#1 And 2) - Christie 4K40-RGB Series Service Manual

Hide thumbs Also See for 4K40-RGB Series:
Table of Contents

Advertisement

Ventilation and cooling

Vents and louvers provide ventilation, both for intake and exhaust, keeping the projector components
within their operating temperature specifications.
Do not install the projector near a radiator, heat register, or within an enclosure. To ensure adequate
airflow, follow the requirements specified in the line drawing (P/N: 020-102976-XX) and never block or
cover the vents.
When replacing fans, ensure you confirm the fan direction for airflow. The correct orientation of the
fan also ensures that the fan harness reaches the connector.

Replacing the HIP blowers (#1 and 2)

The HIP blowers cool the HIP printed circuit board.
1. Remove the rear cover (on page 33).
2. Remove the electronics-side cover (on page 34).
3. Disconnect the J3, J5, J26, and the red, green, and blue mini-SAS harnesses from the card
cage.
4. Loosen the four captive screws securing the card cage and remove the card cage.
5. Disconnect the inline fan connector for the blower, routing the wiring free.
6. Remove the two screws from the affected blower to release it.
7. Replace the blower.
8. To re-install, repeat these steps in reverse order.
Make sure the harnesses route properly and do not get pinched.
4K40-RGB Series Service Guide–D4K40-RGB, Roadie 4K40-RGB, Mirage 4K40-RGB
020-102960-02 Rev. 1 (12-2019)
Copyright
2019 Christie Digital Systems USA, Inc. All rights reserved.
©