Safety Function In Accordance With En Iso 13849 - Festo MS6-SV E-10V24 Series Instructions Manual

Soft start/quick exhaust valve
Hide thumbs Also See for MS6-SV E-10V24 Series:
Table of Contents

Advertisement

Product Overview
Switching behaviour diagrams, with multi-pin plug socket NECA-S1G9-P9-MP1 è Fig.20 and with
multi-pin plug socket NECA-S1G9-P9-MP3/MP5 è Fig.23.
Status of valve
Control for pressurisation by EN1 and EN2
Control for exhaust through EN1 and EN2
Malfunction (red LED flashing)
Supply voltage is not connected
Tab. 5 Switching statuses of the signal contact
Switch-through pressure/filling time
The flow control screw in the cover generates a gradual pressure build-up of outlet pressure p2. The
pressure rise can be adjusted by turning the flow control screw. When the outlet pressure p2 reaches
about 50% of the operating pressure p1, the valve opens and the maximum flow rate performance is
enabled.
1 Ratio of p2 to p1 [%]
Fig. 11 Switch-through pressure tolerance field
Example:
At an operating pressure of p1 = 4 bar with reference to the approved tolerance of ± 20% a switch-
through pressure of 1.2 to 2.8 bar is permissible.
5.3

Safety function in accordance with EN ISO 13849

The product is a safe, redundant mechatronic system designed for implementation of the safety func-
tions:
Safe venting
Protection against unexpected pressure build-up (pressurisation).
Festo — MS6-SV-...-E-10V24 — 2019-10d
Signal contact
Open
Closed
Open
Open
2 Time axis
15

Hide quick links:

Advertisement

Table of Contents
loading