2. Commissioning
Configuring
2-20
(Prerequirements: You have copied the icon file as de-
scribed in step 2 of the preparations).
3. Double-click on the icon of the valve terminal 4.
The mask "Slave properties" will appear 5.
4. Select the slave address identical to the selected setting
on the rotary switch/DIL switch (see chapter 1.2.1) in the
slave and confirm.
Station selection is then completed.
Configuration with COM PROFIBUS 5.0
Prerequirements:
The device data base files must be in the directory of your
PC/programmer.
The mask "Bus parameter" must be edited (bus profile,
baud rate).
The PROFIBUS address must be assigned (see above).
The station type "FESTO CP FB13" must be selected
(see above).
Access the mask "Configure"
1. Click with the right-hand mouse key on the icon of the
valve terminal.
2. Now click "Configure" in the menu which appears.
The mask "Configure" will appear (Fig. 2/10).
Festo P.BE-CP-FB13-E-EN en 0112e