Product overview
Sequence Activity
Optional, when using a third proximity switch S3
3.
Record edge change at proximity switch S3. S3 = 0
Corresponding reaction times
Diagnostics in normal position
Pay attention to forced switch on/off
1.
Apply voltage to pilot valve V1.
2.
Record edge change at proximity switch S1. S1 = 1
3.
Switch off voltage to pilot valve V1.
4.
Record edge change at proximity switch S1. S1 = 0
5.
Apply voltage to pilot valve V2.
6.
Record edge change at proximity switch S2. S2 = 1
7.
Switch off voltage to pilot valve V2.
8.
Record edge change at proximity switch S2. S2 = 0
Corresponding reaction times
Tab. 6 Recommendation for activation and diagnostics
5.3
Safety function in accordance with EN ISO 13849
The product achieves a performance level for the following safety functions:
–
Safe venting
–
Protection against unexpected start-up (pressurisation) after EN 1037
NOTICE!
Failure of the safety function.
Common cause failures (CCF) cause the failure of the safety function, since in this case both channels
in a two-channel system fail simultaneously.
If measures to control the CCFs are not observed, the safety function of the soft-start/quick exhaust
valve can be impaired.
•
Make sure that the described measures are observed
è Failures due to a common cause (Common Cause Failure – CCF).
è 14.4 Safety engineering characteristics
NOTICE!
Failure of the safety function.
Non-compliance with the technical data can lead to loss of the safety function.
•
Observe the technical data è 14 Technical data.
12
Fig.3.
è
14.4 Safety engineering characteristics.
è
Fig.3.
è
Status and status transitions
1
è
V1 = 1
0
è
V1 = 0
1
è
V2 = 1
0
è
V2 = 0
1
è
Festo — MS6-SV-...-D-10V24 — 2019-05b