Digi Connect WAN Series User Manual page 114

Hide thumbs Also See for Connect WAN Series:
Table of Contents

Advertisement

Digi Connect WAN Family web interface
Send when data is present on the serial line: Send the data to the network destinations
n
when a string of characters is detected in the serial data. To enter non-printable characters,
use these key sequences:
Character
hexadecimal
values
tab
line feed
backslash
Match string: A 1 to 4 character string. This is usually the newline character sequence but can
n
also be a custom string of 1 to 4 characters.
Strip match string before sending: Search for the string specified in the Match String field
n
before sending the data and strip the string from the string from the data before it is sent to
the destination.
Send after the following number of idle milliseconds: Send the data after the specified
n
number of milliseconds have passed with no data received on the serial port.
Send after the following number of bytes: Send the data after the specified number of
n
bytes have been received on the serial ports.
Close connection after the following number of idle seconds: Enable to close an idle
n
connection. Use the Timeout field to enter the number of seconds that the connection will be
idle before it is closed. This can be 1 to 65000 seconds.
Close connection when DCD goes low: When selected, the connection will be closed when the
n
DCD (Data Carrier Detected) signal goes low.
Note
If you are using 8-wire cabling, you must apply the altpin for DCD functionality.
Close connection when DSR goes low: When selected, the connection will be closed when the
n
DSR (Data Set Ready) signal goes low.
UDP settings
These UDP Settings are available only when the current port is configured with the Console
management, the UDP Sockets, or the Custom Profile.
Send Socket ID: Include an optional identifier string with the data sent over the network.
n
The Socket ID can be 1 to 256 ASCII characters. Enter non-printable characters as
follows:
Digi Connect WAN Family User Guide
Key
Sequence
\xhh
\t
\n
\\
Configuration through the web interface
114

Advertisement

Table of Contents
loading