Country-
Level Display/
spec. Set-
Setting
tings
SPD monitoring
1
2
3
4
4
SPD monitoring
Status
Password protection
Status
Digital IO modules
1
2
3
4
4
DIO1
DIO2
DIO3
DIO4
Relay
1
2
3
4
4
Relay
Positive logic | Neg-
ative logic
inactive | active
Logging Management
1
2
3
4
Settings
1
2
4
4
3
User logging interval
1
2
3
4
4
1 | 5 | 10 | 15
[minutes]
Service logging interval
1
2
3
4
4
0 – xxx [s]
Yield counter
1
2
3
4
4
0 – xxx [kWh]
Operating hour counter
1
2
3
4
4
0 – xxx [hour]
Analyze Log Data
1
2
3
4
4
User logs
cosPhi | fac (Hz) |
lac 1 (A) | lac2 (A) |
lac3 (A) | idc (A) | Qac
(var)
Parameter Manage-
1
2
3
4
ment
KACO blueplanet 87.0 TL3 KACO blueplanet 92.0 TL3 KACO blueplanet 110 TL3 KACO blueplanet 125 TL3
KACO blueplanet 137 TL3 KACO blueplanet 150 TL3
Action in this menu/meaning
NOTE: Opportunity to check the overvoltage protection with appropri-
ate status messages.
1 Activate overvoltage protection.
2 Activate optional password protection.
3 Confirm the action field.
NOTE: Opportunity to use digital inputs/outputs via an expansion
module (KACO accessory).
↻ Expansion module detected at one of the two slots.
1 Select the logic of the 4 channels.
2 Confirm the action field.
NOTE: Opportunity to configure the fault signal relay [ERR].
1 Select the type of logic.
2 Select the form of activity.
3 Confirm the action field.
NOTE: Input screens for log and service data and default settings.
Specify the interval for data capture and base meters.
F Specify the time period between 2 log data recordings.
F Specify the time period between 2 log data recordings.
NOTE: Opportunity to enter yield data when exchanging a device.
F Enter the meter reading in the input field.
NOTE: Opportunity to transfer the operating hours of a replacement
device.
1 Enter the hours in the input field.
2 Confirm the action field.
NOTE: All measurement data can be transferred to a USB stick by mak-
ing individual and multiple selections.
1 Select a date in the calendar.
2 Select measurement data from the dropdown field.
3 Update the measurement data.
4 Move the selected measurement data to the storage device or
move the data selectively.
NOTE: Option to reset set values as well as to import and export spe-
cific parameters.