No. Grid
LED Display on web interface
LED
203
Protection shutdown grid
voltage (effective value) L1
204
Protection shutdown grid
voltage (effective value) L2
205
Protection shutdown grid
voltage (effective value) L3
206
Protection shutdown over-
current HW
207
Detection of hardware de-
tection failed: Control card
208
Detection of hardware de-
tection failed: AC power
board
209
Detection of hardware de-
tection failed: AC relay
board
216
Protect. shutdown HW -
overvoltage DC link halves
217
Protect. shutdown HW - 24V
supply voltage
224
External limitation
226
The inverter is disconnected
from the grid manually
Page 106
Status description
Protective shutdown due to an excessively
high grid voltage on Lx. It is the effective value
which is decisive for the shutdown procedure.
See description in the event of a fault 203
See description in the event of a fault 203
Overcurrent shutdown triggered by hardware. -
The data saved on the control card is erro-
neous.
The data saved on the AC power board is erro-
neous.
The data saved on the AC relay board is erro-
neous.
One of the two DC link halves has exceeded
the maximum value. Shutdown occurs by way
of HW-detection and TripZone shutdown.
The supply voltage in the device has exceeded
its max. permitted value. Shutdown occurs by
way of HW-detection and TripZone shutdown.
This is a relative specification of the desired
active power adjustment.
The inverter can be disconnected from the grid
manually after logging in via the WebGui or
the button on the housing. This message then
appears.
KACO blueplanet 87.0 TL3 KACO blueplanet 92.0 TL3 KACO blueplanet 110 TL3 KACO blueplanet 125 TL3
Action
Check the AC-side
wiring (e.g. in-
creased voltage due
to inductance capa-
city of a trans-
former) If the error
display occurs fre-
quently, or every
time, the installa-
tion must be
checked. If there is
nothing wrong with
the installation,
then there is a fault
in the device.
Check connection/
cabling!
See action in the
event of a fault 203
See action in the
event of a fault 203
Disconnect AC and
DC, wait 1 minute
and switch on again.
Disconnect AC and
DC, wait 1 minute
and switch on again.
Disconnect AC and
DC, wait 1 minute
and switch on again.
Disconnect the AC
and DC supply. Wait
1 minute and switch
back on.
Disconnect the AC
and DC supply. Wait
1 minute and switch
back on.
-
Switch on the grid
by pressing the
function button for
a long time (> 5 sec)
[Chapter 9.6.1] or
activate the grid
connection using
the web interface
symbol.