Country-
Level Display/
spec. Set-
Setting
tings
Constant voltage mode
1
2
3
4
4
Constant voltage
875 – 1300 [V]
Constant voltage mode
Off | On
DC starting voltage
1
2
3
4
4
1000 – 1450 [V]
Insulation resistance
1
2
3
4
4
100 – 2000 [kOhm]
Grid Parameters
1
2
3
4
Country & Grid type
1
2
3
4
4
Nominal grid voltage &
Nominal grid frequency
Password protection
Status
3-phase monitoring
1
2
3
4
4
On / Off
FRT (Fault Ride
1
2
3
4
4
Through)
Operation mode –
1
2
4
4
3
On | Off
Setting | Manual |Pre-
defined zero current
Priority – Reactive cur-
rent limitation | Active
current priority
KACO blueplanet 87.0 TL3 KACO blueplanet 92.0 TL3 KACO blueplanet 110 TL3 KACO blueplanet 125 TL3
KACO blueplanet 137 TL3 KACO blueplanet 150 TL3
Action in this menu/meaning
NOTE: Opportunity to deactivate the MPP seek mode in order to oper-
ate the device with a constant DC voltage.
F Set value for constant voltage control.
1 Activate or deactivate the constant voltage controller.
2 Confirm the action field.
NOTE: The device begins feed-in as soon as this DC voltage is present.
1 Set the starting voltage.
2 Confirm the action field.
1 Set threshold value (in 1kOhm increments) at which the insulation
monitor reports a fault.
2 Confirm the action field.
Input screens for network parameters
NOTE: This option influences the country-specific operating settings of
the device. Please consult KACO Service for further information.
NOTE: . Configuration via web user interface [See sec-
tion 9.4.2} Page 65]
F Select country and grid type.
F Specify optional nominal grid voltage.
NOTE: The device switches off if the grid frequency deviates from the
nominal grid voltage by more than 9.5Hz.
1 Select optional nominal grid frequency.
2 Activate optional password protection.
3 Confirm the action field.
NOTE: The device is equipped with redundant 3-phase monitoring. If
the grid voltage exceeds or drops below the configured values, the
device switches off. The minimum switch-off threshold can be set in
1 V increments.
F Activate or disable monitoring.
NOTE: The device supports dynamic grid stabilization (Fault Ride-
Through).
F Select a control process.
On: Activates dynamic grid support using dynamic reactive current.
Off: Deactivates dynamic grid support using dynamic reactive current.
Dynamic grid support remains active on account of immunity to inter-
ference.
F Select a control process.
F Select a control process.
Page 49