Transmitter General Specifications; Max. Operating Temperature Of Ped Specification - Oval ALTI mass CA00A Instructions Manual

Table of Contents

Advertisement

L -- 740 -- 28 -- E

3.1.4 Transmitter general specifications

Item
Model
Power source
Power consumption
Ambient temperature
Transmission length
(separately-located type)
Applicable EU directive
Applicable EN standards
Explosionproof configuration
Maritime certification
Dusttight, waterproof configuration
Transmitter construction
Finish
Display
Weight
Communication interface
※Optional except for HART
Damping (default)
Low flow cutoff (default)
Pulse output (※5)
Analog output (※5)
Status output (※5)
Status input (※5)
Other standard
NOTES
※1: Below -20℃, the display loses its visibility due to weakened contrast. Both the display and infrared
sensor may exhibit slow responses below -20℃.
      
※2: If signal cable length exceeds Max transmission length, consult the factory.
※3: Of the two analog output systems,only analog output 1 is available for HART communication.
※4: Of error outputs, "zero adjust is in progress" status output can also be set up.
※5: When FOUNDATION Fieldbus, PROFIBUS PA is selected as the communication interface, all input and
output signals will be turned off.
※6: The Type S stainless steel tube type does not support the density output.
Fixed density is used for the volume output.
※: Denoising parts are embedded in the lines between power source, output, communication, and the
chassis.
Lower the applied voltage to the following levels in order to conduct insulation test or withstand voltage
test on these lines.
AC:200V, DC:250V

3.1.5 Max. operating temperature of PED specification

PED Specifications (Maximum operating pressure)•••CA040 to CA250
Operating
ASME Flange Rating
Temperature
150 lb
to 38℃
1.90
to 50℃
1.84
to 100℃
1.62
to 150℃
1.48
to 200℃
1.37
to 250℃
1.21
to 300℃
1.02
to 350℃
0.84
① For CA20H and CA250, 8.8MPa is max. operating pressure
② For CA20H and CA250, 8.5MPa is max. operating pressure
③ For CA20H and CA250, 7.4MPa is max. operating pressure
④ For CA20H and CA250, 6.7MPa is max. operating pressure
⑤ For CA20H and CA250, 6.2MPa is max. operating pressure
※: Only SUS316L is available as the major parts material.
1
85 to 264VAC, 50 / 60Hz (Safety rated 100 to 240VAC 50/60Hz) or 20 to 30VDC
Type U
Stainless steel tube type: 50 meters max. (using dedicated interconnect cable) (※2)
Type S
Titanium tube type: 100 meters max. (using dedicated interconnect cable) (※2)
Type B
EMC :EN61326-1:2013 ClassA
ATEX :EN60079-0:2012 EN60079-1:2007 EN60079-11:2012
IECEx:IEC60079-0:2011 IEC60079-1:2007-04 IEC60079-11:2011
LVD   :EN61010-1:2010
Body: Munsell 10B8/4 Covers (front and rear): Munsell 2.5PB4/10
LCD display (128×64dots) Backlight (white and orange)
2 infrared optical sensors and 2 LEDs (green and red)
Integrally mounted type 3.6kg; Separately mounted type 5.0kg
HART
HART protocol 7, Bell202 (※3)
(standard)
RS-485 Modbus protocol, Baudrate : 9600bps, 19200bps, 38400bps
Modbus
RTU or ASCII, Response time : 25 to 50 ms
FOUNDATION
AI block×4, IT block×2, with Link Master function
Fieldbus
PROFIBUS PA AI block×4, TOT block×2
Open drain output (equivalent to open collector output) [Min. 10V to Max. 30V,
50mADC, ON resistance 0.6Ωor less] or
Voltage pulse (Low Level : 1.5V max. High Level : 13V min. Output impedance: 2.2kΩ)
Setting range: 0.1 to 0000Hz (Max. output 11000Hz)
Select 2 outputs from instant flowrate (mass or volume), temp., and density. (※6)
Open drain output (equivalent to open collector output) [Max. 30V, 50mADC,
ON resistance 0.6Ωor less] or
Select one from error (※4), flow direction, and high/low alarm (default is error).
Contact-closure input (Form "a" input) Short: 200Ω max. Open: 100kΩ min.
Select one from "remote zero adjust" total reset, 0% signal lock, and function OFF
(default is function OFF).
300 lb
600 lb
PN10
4.96
9.93 ①
1.00
4.81
9.62 ②
1.00
4.22
8.44 ③
1.00
3.85
7.70 ④
0.90
3.57
7.13 ⑤
0.84
3.34
6.68
0.79
3.16
6.32
0.74
3.03
6.07
0.71
Description
PA0K
15W max.
40 to +55°
C (※1)
200 meters max. (using dedicated interconnect cable) (※2)
5 meters max. (using dedicated interconnect cable) (※2)
EMC Diective :2014/30/EC
ATEX Diective:94/9/EC
LVD Diective
:2014/35/EU
Refer to section 10.4
DNV GL (Refer to section 12)
IP66 / 67
Integrally mounted or separately mounted
Flowrate 0.8sec, density 4sec, temp. 2.5sec
}
Type U 0.6%
or less of maximum
Type S 1.5%
normal flowrate
Type B 1.0%
4 to 20mADC Max. load 600Ω
OIML R117-1:2007
MID (WELMEC 7.2, 8.8)
DIN Flange Rating
PN16
PN25
1.60
2.50
1.60
2.50
1.60
2.50
1.45
2.27
1.34
2.10
1.27
1.98
1.18
1.85
1.14
1.78
Unit: MPa
PN40
4.00
4.00
4.00
3.63
3.37
3.18
2.97
2.85

Hide quick links: