9.10 Reset Function

The transmitter is provided with two pulse outputs along with two counters (1 and 2) and two totalizers
(1 and 2) which work in sync with pulse output. If it is desired to reset one particular counter and its
associated totalizer, follow the procedure outlined below. (Since the totalizer counts pulses coming in from
the counter, you cannot reset them independently.)
The procedure to reset the counter / totalizer 1 to 0 is described here as an example. The same
procedure applies to the other pair.
Click "SEL1".
Click "SEL3".
Click "ENT".
Click "ENT".
Click "SEL3".
Click "ENT".
Click "ENT".
NOTE:
This function is disabled in Write Protect mode
(refer to section 9.2).
(1) Bring up the item of function you want to use.
Firstly, proceed key operation to show counter/totalizer 1 reset (Cnt/Ttl Reset )
screen.
(For the procedure to view individual items, see 9.2.2 thru 9.2.7 Transition chart.)
When the cursor is placed over counter/totalizer 1 reset (Count/Total 1), click "SEL1"
to bring up the Count/Total 1 reset screen.
(2) Decide whether to reset to 0 or not.
The present counter reading is indicated.
If you want to reset to 0, click "SEL3". The next screen appears and the counter
reads 0.
If you want to cancel the reset process, click "ENT" and then click "SEL3".
The window then returns to menu select screen.
(3) The present counter reading after the reset operation is indicated.
If you want to abort the reset process, click "ENT" followed by clicking "SEL3"
and the window returns to menu select screen.
If you want to reset to 0 once again, click "SEL3".
Click "SEL3".
Click "SEL3".
L -- 740 -- 28 -- E