Csa Explosionproof - Oval ALTI mass CA00A Instructions Manual

Table of Contents

Advertisement

L -- 740 -- 28 -- E

10.4.4 CSA explosionproof

Converter:
Detector:
Applicable standard:
 
Detector
 
Transmitter
● Integral type
Converter symbol:
Detector symbol:
Ambient temp.:
Detector to be connected: CA006 to CA250
Field temp.:
Power source:
Allowable voltage:
Communication:
● Separate type
Transmitter symbol:
  
Detector symbol:
Converter Ambient Temp.: -40℃ to +55℃
Detector Ambient Temp.: As shown on Detector Model Specification Table 2
Fluid Temp.:
Power source:
Allowable voltage:
Communication:
10
70007590
70011628
CAN/CSA Standard C22.2 No. 0-10
CAN/CSA-C22.2 No.61010-1-12 (3rd Edition)
UL Std. No. 61010-1 (3rd Edition)
CAN/CSA Standard C22.2No. 60079-0:11
ANSI/UL 60079-0 (2009)
CAN/CSA-C22.2 No.60079-11:11
IEC 60079-11 Edition 6
UL ND 60079-11(Ed. 6)
CAN/CSA Standard C22.2 No. 0-10
CAN/CSA-C22.2 No. 61010-1-12 (3rd Edition)
UL Std. No. 61010-1 (3rd Edition)
CAN/CSA Standard C22.2 No. 60079-0:11 December 2011
CAN/CSA Standard C22.2 No. 60079-1:11 December 2011
CAN/CSA-C22.2 No. 60079-11:11 December 2011
ANSI/UL 60079-0 (2009) Fifth Edition
ANSI/UL 60079-1 (2009) Sixth Edition
ANSI/UL 60079-11 (2013) Sixth Edition
ClassⅠ, Zone 1, Ex d ib ⅡC T4 Gb
ClassⅠ, Zone 1, AEx d ib ⅡC T4 Gb
(CA, CB, CS series integral type)
ClassⅠ, Zone 1, Ex ib ⅡC T4 Gb
ClassⅠ, Zone 1, AEx ib ⅡC T4 Gb
-40℃ to +55℃ (-20℃ to +55℃ when connected with CS080 and CB040/050)
CB006 to CB050
CS010 to CS080
As shown on Detector Model Specification Table 2
AC85 to 250V 50/60Hz, or DC20 to 30V
Um=250V
HART, Modbus PROFIBUS and FOUNDATION Fieldbus (FISCO)
ClassⅠ, Zone 1, Ex d [ib] ⅡC T6 Gb
ClassⅠ, Zone 1, AEx d [ib] ⅡC T6 Gb
CA series: ClassⅠ, Zone 1, Ex ib ⅡC T1, T2, T3, T4, T5 Gb
ClassⅠ, Zone 1, AEx ib ⅡC T1, T2, T3, T4, T5 Gb
CB series: ClassⅠ, Zone 1, Ex ib ⅡB T3, T4 Gb
ClassⅠ, Zone 1, AEx ib ⅡB T3, T4 Gb
CS series: ClassⅠ, Zone 1, Ex ib ⅡC T3, T4 Gb
ClassⅠ, Zone 1, AEx ib ⅡC T3, T4 Gb
As shown on Detector Model Specification Table 2
AC85 to 250V 50/60Hz, or DC20 to 30V
Um=250V
HART, Modbus PROFIBUS and FOUNDATION Fieldbus (FISCO)