L -- 740 -- 28 -- E

14.2.2 Titanium tube type

Meter size/Nominal Diameter
Main code
① ②
Model
ALTI mass Type S
C S
③ ④ ⑤
Meter size/Nominal Diameter
JIS flange
0 1 0
10mm
0 1 5
15mm
0 2 5
25mm
0 4 0
40mm
0 5 0
50mm
R 5 0
80mm
⑥ —
Density range
1
Low density liquids (0.5 to 1.0g/mL)
Ordinary density (0.7 to 1.3g/mL)
2
3
High density liquid (1.0 to 1.5g/mL)
Temp. category ※1
Standard (130℃ and lower)
1
Major parts material
T
SB338 Grade-9 + TB480H ※2
⑩ ⑪
Process connection
J 1 JIS10K
J 2 JIS20K
A 1 ASME150
P 1 JPI150
H S ISO Ferrule
Z 9 Special
⑫ —
Explosion-proof ※3
0 Non-explosionproof
1 TIIS
2 ATEX/IECEx
3 KCs
※4
4 CSA (C-US)
5 EAC
※4
7 NEPSI
※4
※1: Explosionproof specifications are restricted based on temperature class.
※2: If it is necessary to use the existing transmitter, consult OVAL.
※3: For CSR50, applicable explosionproof specifications are TIIS, ATEX, and IECEx only.
※4: "2, 3" for "Communication interface  " are in preparation and is not available yet.
※5: If temperature of the fluid exceeds 80℃ for explosionproof types, only "Separately mounted" type is available for the transmitter construction.
In case of non-explosionproof, integral type can be used up to 130℃ by restricting the transmitter ambient temp. to 45℃ at max.
10
Ex-proof temp. class
Explosion-proof
Process connection
Major parts material
Temp. category
Density range
Model
ASME•JPI flange
Ferrule
1/2"
10A
1/2"
15A
1"
38 (ISO), IDF 1.5S
1·1/2"
51 (ISO), IDF 2S
2"
63.5 (ISO), IDF 2.5S
3"
88.9 (ISO), IDF 3.5S
Regulations
Transmitter
Transmitter construction
Main code
Ex-proof temp. class
0 Non-explosionproof
3 T3
4 T4
Regulations
0 Standard
E EHEDG (CS025, CS040, CS050) + w/Material test certificate
T Fire Service Act
S Ship Classification Society Pattern Approval
P Ship Classification Society Pattern Approval + w/Material test certificate
F w/Material test certificate
⑯ —
Transmitter
ALTI mass
1
Transmitter construction ※5
1 Integrally mounted
2 Separately mounted
Power source
1 20 to 30VDC
2 85 to 264VAC (Safety rated 100 to 240VAC 50/60Hz)
Pulse
0 When "2, 3" are chosen for "Communication interface  "
B Voltage pulse
G Open drain pulse (equivalent to open collector pulse) (standard)

Communication interface
HART communication (HART protocol version 7, Bell202)
1
2 FOUNDATION Fieldbus H1communication (ITK version6)
3 PROFIBUS PA communication (Profile version3.02)
Modbus communication (RS-485 Modbus protocol)
4

Version code
A
Version code: A
 —

Special shape designation
0 Standard
Z Special shape (including polishing, long neck)
Power source
Pulse
Communication protocol
Version code
Special shape designation
/ / / Additional code
※w/Material test certificate

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents