Shipping Parameters - Oval ALTI mass CA00A Instructions Manual

Table of Contents

Advertisement

L -- 740 -- 28 -- E

■ Shipping Parameters

Given below is the explanation of parameters found in the parameter list attached to the product.
No.
Item
Device information
1
Tag
2
Long Tag
3
Descriptor
4
Message
5
Date
6
Dev ID
7
Final asmbly num
8
Snsr s/n
9
Snsr model
10
Flange
11
Snsr matl
12
Hardware rev
Sensor type
13
Sensor type
14
Mass flow USL
15
Mass flow LSL
16
Temperature USL
17
Temperature LSL
18
Vol flow USL
19
Vol flow LSL
20
Density USL
21
Density LSL
Flow
22
Mass flow unit
23
Vol flow unit
24
Flow direction
25
Flow damp (Mass)
26
Flow cutoff
27
Vol flow coef
Density
28
Unit
29
Damp
30
Slug low limit
31
Slug high limit
32
Slug duration
33
Compensation
34
Standard temp
35
Expansion coef
36
Settied density
37
Density Value
Temperature
38
Unit
39
Damp
Analog output 1
40
Assign
41
URV
42
LRV
43
Lowcut
44
Added damp
Analog output 2
45
Assign
46
URV
47
LRV
48
Lowcut
49
Added damp
1
Description
Tag number (8-character)
Tag number (32-character)
Description
Message
Date of manufacture
Device ID
Final assembly number
Sensor serial number
Sensor model
Flange rating
Sensor material
Hardware revision
Sensor type
Mass flow max. allowable range
Mass flow min. allowable range
Temperature max. allowable range
Temperature min. allowable range
Volume flow max. allowable range
Volume flow min. allowable range
Density max. allowable range
Density min. allowable range
Instantaneous mass flow unit
Instantaneous volume flow unit
Flow direction setting
Flow (Mass) damping
Flow (Mass) cutoff
Volume flow correction coefficient
Density unit
Density damping
Lower density limit of gas multiphase flow detection
Upper density limit of gas multiphase flow detection
Time duration of gas multiphase flow detection
Standard temp. compensation setting
Standard temperature
Expansion coefficient
Fixed density compensation setting
Fixed density value
Temperature unit
Temperature damping
Analog output 1 assignment
Analog output 1 setting at 20mA
Analog output 1 setting at 4mA
Analog output 1 low-cut
Analog output 1 added damping
Analog output 2 assignment
Analog output 2 setting at 20mA
Analog output 2 setting at 4mA
Analog output 2 low-cut
Analog output 2 added damping
Factory setting
Setting
Continued on next page➡