L -- 740 -- 28 -- E

14.2 Type S

14.2.1 Stainless steel tube type

Meter size/Nominal Diameter
Main code
① ② Model
C S ALTI mass Type S
③ ④ ⑤ Meter size/Nominal Diameter
JIS flange
0 1 0
15mm
0 1 5
15mm
0 2 5
25mm
0 4 0
40mm
0 5 0
50mm
0 8 0
80mm
⑥ —
⑦ Density range
1 Low density liquids (0.5 to 1.0g/mL)
2 Ordinary density liquid (0.7 to 1.3g/mL)
3 High density liquid (1.0 to1.5g/mL)
⑧ Temp. category ※1
1 Standard (130℃ and lower)
⑨ Major parts material
S SUS316L
⑩ ⑪ Process connection
J 1 JIS10K
J 2 JIS20K
A 1 ASME150
P 1 JPI150
H S ISO Ferrule
Z 9 Special
⑫ —
⑬ Explosion-proof
0 Non-explosionproof
1 TIIS ※2
2 ATEX/IECEx
3 KOSHA/KTL ※2
4 CSA (C-US) ※2
5 EAC ※2
7 NEPSI ※2
⑭ Ex-proof temp. class
0 Non-explosionproof
3 T3
4 T4
※1: Explosionproof specifications are restricted based on temperature class.
※2: "2, 3" for "Communication interface  " are in preparation and is not available yet.
※3: CS080 is not conform to (the Japan) High Pressure Gas Act.
※4: If temperature of the fluid exceeds 80℃ for explosionproof types, only "Separately mounted" type is available for the transmitter construction.
In case of non-explosionproof, integral type can be used up to 130℃ by restricting the transmitter ambient temp. to 45℃ at max.
1
Ex-proof temp. class
Explosion-proof
Process connection
Major parts material
Temp. category
Density range
Model
ASME•JPI flange
Ferrule
1/2"
15A
1/2"
15A
1"
38 (ISO), IDF 1.5S
1·1/2"
51 (ISO), IDF 2S
2"
63.5 (ISO), IDF 2.5S
3"
※Consult with OVAL
Regulations
Transmitter
Transmitter construction
Main code
⑮ Regulations
0 Standard
High Pressure Gas Safety Act
G
(Approved product)
High Pressure Gas Safety Act
H
(Individual test)
High Pressure Gas Safety Act
J
(Completion inspection)
T Fire Service Act
S Ship Classification Society Pattern Approval
P Ship Classification Society Pattern Approval + w/Material test certificate
F w/Material test certificate
⑯ —
⑰ Transmitter
1 ALTI mass
⑱ Transmitter construction ※4
1 Integrally mounted
2 Separately mounted
⑲ Power source
1 20 to 30VDC
2 85 to 264VAC (Safety rated 100 to 240VAC 50/60Hz)
⑳ Pulse output type
0 When "2, 3" are chosen for "Communication interface  "
B Voltage pulse
G Open drain pulse (equivalent to open collector pulse) (standard)
 Communication interface
1 HART communication (HART protocol version 7, Bell202)
2 FOUNDATION Fieldbus H1communication (ITK version6)
3 PROFIBUS PA communication (Profile version3.02)
4 Modbus communication (RS-485 Modbus protocol)
 Version code
A Version code: A
 —
 Special shape designation
0 Standard
Z Special shape (including polishing)
Power source
Pulse
Communication interface
Version code
Special shape designation
/ / / Additional code
※w/Material test certificate
※3
※w/Material test certificate
※3
(Designed on PO issued)
※w/Material test certificate
※3
※w/Material test certificate