Type S Product Codes - Oval ALTI mass CA00A Instructions Manual

Table of Contents

Advertisement

L -- 740 -- 28 -- E

15.2 Type S product codes

Item
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ ⑬ ⑭ ⑮ ⑯ ⑰ ⑱
Model
C S
0 1 0
0 1 5
0 2 5
Nominal size
0 4 0
0 5 0
R 5 0
0 8 0
H
Fluid category
M
L
Temp. category (※1)
Pressure category
Major parts material (※9)
Process connection
Transmitter construction (※2)
Power source
Analog output (※3, 4)
Pulse output (※3, 4)
Pulse output type (※3)
Communication interface
Explosionproof rating (※8)
Explosionproof temperature class
NOTES
※1:Explosionproof specification has restrictions on temperature class.
※2:If temperature of the fluid exceeds 80℃, only "Separately mounted" type is available for the transmitter construction.
※3:When FOUNDATION fieldbus, PROFIBUS is selected for communication interface,
    product code categories of analog output is "X" and pulse output is "X" (pulse output type:"0").
※4:When "Volume flow (fixed density)" is selected for analog output or pulse output, fixed density will be applied.
※5:JIS connection is 10mm for the titanium tube type.
※6:Available only for the titanium tube type.
※7:Communication interfaces "FOUNDATION fieldbus H1 communication" and "PROFIBUS PA communication" are
unavailable. (in preparation)
      ※8:Applicable explosionproof rating for CSR50 are TIIS, ATEX, and IECEx only.
      ※9:If the major parts material ⑨ is "T", your existing transmitter may not be compatible. If you plan to use the existing
transmitter, contact OVAL.
The new product code has been implemented since April 2017.
※:
Therefore, the product code explanation of the old product code will not be updated after April 2017.
Contact OVAL for any inquiries about the old product code.
1
Product Code
1
1
S
T
B
C
D
H
L
Z
1
2
1
2
A
B
C
D
E
F
G
H
J
K
X
A
B
C
D
E
F
G
H
J
K
X
0
1
2
1
2
3
4
0
1
2
3
4
5
7
ALTImass Type S
15mm connection (1/2") (※5)
15mm connection (1/2")
25mm connection (1")
40mm connection (1・1/2")
50mm connection (2")
80mm connection (3") Titanium Tube Type only
80mm connection (3") Stainless Steel Tube Type only
High density liquid (1.0 to1.5g/ml)
Ordinary density liquid (0.7 to 1.3g/ml)
Low density liquids (0.5 to 1.0g/ml)
Standard (below 130° C)
Standard
SUS316L (except for CSR50) Stainless Steel Tube Type only
SB338 Grade-9+TB480H (except for CS080) Titanium Tube Type only
Ferrule
JIS 10K
JIS 20K
ASME 150
JPI 150
Other than above
Integrally mounted
Separately mounted
20 to 30VDC
85 to 264VAC (Safety rated 100 to 240VAC), 50/60Hz
Output 1: Mass flow
Output 2: Mass flow
Output 1: Mass flow
Output 2: Density(※6)
Output 1: Mass flow
Output 2: Temperature
Output 1: Mass flow
Output 2: Volume flow (true density)(※6)
Output 1: Mass flow
Output 2: Volume flow (fixed density)
Output 1: Density
Output 2: Temperature(※6)
Output 1: Volume flow (true density)
Output 1: Volume flow (fixed density)
Output 1: Volume flow (true density) Output 2: Temperature(※6)
Output 1: Volume flow (fixed density) Output 2: Temperature
Non-output
In the case of FOUNDATION fieldbus,PROFIBUS communication
Output 1: Mass flow
Output 1: Volume flow (true density )(※6)
Output 1: Volume flow (fixed density)
Output 1: Mass flow
Output 2: Mass flow
Output 1: Mass flow
Output 2: Volume flow (true dens.)(※6)
Output 1: Mass flow
Output 2: Volume flow (fixed density)
Output 1: Vol. flow (true dens.) Output 2: Vol. flow (true dens.)(※6)
Output 1: Vol. flow (fixed dens.) Output 2: Vol. flow (fixed dens.)
Output 1: Volume flow (true dens.)
Output 1: Volume flow (fixed density)
Non-output
In the case of FOUNDATION fieldbus,PROFIBUS communication
Non-output
In the case of FOUNDATION fieldbus,PROFIBUS communication
Open drain pulse (standard)
Voltage pulse
HART communication
FOUNDATION fieldbus H1 communication (※3)
PROFIBUS PA communication (※3)
Modbus communication
Non-explosionproof
TIIS
ATEX, IECEx
KOSHA/KTL (※7)
CSA
GOST (※7)
NEPSI (※7)
0 Non-explosionproof
3 Sensor unit: Temp. class T3, separate transmitter only
4 Sensor unit: Temp. class T4
Description
Output 2: Density(※6)
Output 2: Density(※6)
Output 2: Mass flow(※6)
Output 2: Mass flow
Bell202
ITK version6
Profile version3.02
RS-485 Modbus protocol
Single pulse
Double pulse

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents