10.4.3 KCs Explosionproof

Transmitter: 14-AV4BO-0607 (Integral type), 14-AV4BO-0608 (Separate type)
Detector:
14-AV4BO-0609 (CA 006 to CA150), 15-KA4BO-0192 (CA15H, CA200),
15-KA4BO-0193 (CA20H, CA250), 12-AV4BO-0579 (CB series) and
12-AV4BO-0578 (CS series)
● Integral type
Transmitter symbol:
Detector symbol:
Ambient temp.:
Detector to be connected: CA006 to CA250
Fluid temp.:
Power source:
Allowable voltage:
Communication:
● Separate type
Transmitter symbol:
Detector symbol:
Converter Ambient Temp.: -40℃ to +55℃
Detector Ambient Temp.: As shown on Detector Model Specification Table 2
Fluid Temp:
Power source:
Allowable voltage:
Communication:
Explanation about subject model codes
Model code: C①②③④-x⑤xxx-3⑥x-1⑦⑧x⑨x-x
Position
Meaning
Sensor Series
②③④
Nominal Diameter
Temperature
Classification
Temperature Class
Converter Installation
Structure
Power Source
Communication
Configuration
Ex d ib ⅡB T4
Ex ib ⅡC T4 (CA series)
Ex ib ⅡB T4 (CB, CS series)
-40℃ to +55℃ (-20℃ to +55℃ only when connected with CS080)
CB006 to CB050
CS010 to CS080
As shown on Detector Model Specification Table 2
AC240V 50 / 60Hz, or DC30V
Um= 250V
HART, Modbus, PROFIBUS and FOUNDATION Fieldbus(FISCO)
Ex d[ib]ⅡC T6
Ex ib ⅡC T1, T2, T3, T4, T5 (CA series)
Ex ib ⅡB T3, T4 (CB, CS series)
As shown on Detector Model Specification Table 2
AC240V 50/60Hz, or DC30V
Um=250V
HART, Modbus, PROFIBUS and FOUNDATION Fieldbus(FISCO)
Value
A
CA series
B
CB series
S
CS series
CA00A, CA001, CA003, CA006, CA010, CA015, CA025, CA040, CA050,
00A to 250
CA080, CA100, CA150, CA15H, CA200, CA20H and CA250
006 to 050
CB006, CB010, CB015, CB025, CB040 and CB050
010 to 080
CS010, CS015, CS025, CS040, CS050 and CS080
1
Standard(-40℃ to +130℃)
2
Standard(+130℃ to +200℃)
3
High temp.(+200℃ to +350℃)
4
Low temp.(-200℃ to +50℃)
1
T1: Applicable sensor sizes CA025 to CA150
2
T2: Applicable sensor sizes CA003 to CA250
3 or 4
T3 or T4: All sensor sizes applicable
5
T5: Applicable sensor sizes CA025 to CA250
1
Integrally mounted models
2
Separately mounted models
1
20 to 30VDC
2
85 to 264VAC (Safety Rating: 100 to 240VAC) 50/60Hz
1
HART Communication (HART Protocol Version 7, Bell 202)
2
FOUNDATION Fieldbus H1 Communication (ITK Version 6)
3
PROFIBUS PA Communication (Profile Version 3.02)
4
Modbus Communication (RS-485 Modbus Protocol)
L -- 740 -- 28 -- E
Description
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents