L -- 740 -- 28 -- E

15. PRODUCT CODE EXPLANATION OF THE OLD PRODUCT CODE

15.1 Type U product codes

15.1.1 CA00A to CA080

Product Code
Item
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ ⑬ ⑭ ⑮ ⑯ ⑰ ⑱
Model
C A
0 0 A
0 0 1
0 0 3
0 0 6
Nominal
0 1 0
0 1 5
size
0 2 5
0 4 0
0 5 0
0 8 0
L
Fluid category
G
1
2
Temp. category (※1)
3
4
1
Pressure category
2
Major parts material
Process connection
Transmitter construction (※4)
Power source
Analog output (※5, 6, 7)
Pulse output (※5, 6, 7)
Pulse output type
(※5)
Communication interface
Explosionproof rating
Explosionproof temperature class
NOTES
※1:Explosionproof specification has restrictions on temperature class.
※2:If "High pressure service" is selected for the pressure category, process connection will be "Screw-in".
※3:When "H" (Alloy C) is selected as major part material code, only loose flange is applicable for CA006.
※4:If temperature of the fluid exceeds 80℃, only "Separately mounted" type is available for the transmitter construction.
※5:When FOUNDATION fieldbus, PROFIBUS is selected for communication interface,
    product code categories of analog output is "X" and pulse output is "X" (pulse output type:"0").
※6:When "Volume flow (fixed density)" is selected for analog output or pulse output, fixed density will be applied.
※7:Simultaneous output of both "Volume flow (fixed density)" and "Volume flow (true density)" for analog output and pulse
output is not available.
※8:Communication interfaces "FOUNDATION fieldbus H1 communication" and "PROFIBUS PA communication" are
unavailable. (in preparation)
The new product code has been implemented since April 2017.
※:
Therefore, the product code explanation of the old product code will not be updated after April 2017.
Contact OVAL for any inquiries about the old product code.
1
ALTImass Type U
1/4˝ connection
1/4˝ connection
10mm connection (3/8˝)
10mm connection (3/8˝)
15mm connection (1/2˝)
15mm connection (1/2˝)
25mm connection (1˝)
40mm connection (1・1/2˝)
50mm connection (2˝)
80mm connection (3˝)
Liquid service
Gas service
Standard (below 130° C)
Standard (below 200° C)
High temperature service (below 350° C)
Low temperature explosionproof service (-200° C to +50℃)
Standard
High pressure service (※2)
SUS316L
S
SUS316L + Alloy C
M
Alloy C (※3)
H
Other material
X
Screw-in
A
Ferrule
B
JIS 10K
C
JIS 20K
D
JIS 30K
E
JIS 40K
F
JIS 63K
G
ASME 150
H
ASME 300
J
ASME 600
K
JPI 150
L
JPI 300
M
JPI 600
N
DIN PN 10
P
DIN PN 16
Q
DIN PN 25
R
DIN PN 40
S
Other than above
Z
Integrally mounted
1
Separately mounted
2
20 to 30VDC
1
85 to 264VAC (Safety rated 100 to 240VAC), 50/60Hz
2
Output 1: Mass flow
A
Output 1: Mass flow
B
Output 1: Mass flow
C
Output 1: Mass flow
D
Output 1: Mass flow
E
Output 1: Density
F
Output 1: Volume flow (true density)
G
Output 1: Volume flow (fixed density)
H
Output 1: Volume flow (true density)
J
Output 1: Volume flow (fixed density)
K
Non-output
X
Output 1: Mass flow
A
Output 1: Volume flow (true density)
B
Output 1: Volume flow (fixed density)
C
Output 1: Mass flow
D
Output 1: Mass flow
E
Output 1: Mass flow
F
Output 1: Vol. flow (true dens.)
G
Output 1: Vol. flow (fixed dens.)
H
Output 1: Volume flow (true dens.)
J
Output 1: Volume flow (fixed dens.)
K
Non-output
X
Non-output
0
Open drain pulse (standard)
1
Voltage pulse
2
HART communication
1
FOUNDATION fieldbus H1 communication (※5)
2
PROFIBUS PA communication (※5)
3
Modbus communication
4
Non-explosionproof
0
TIIS
1
ATEX, IECEx
2
KOSHA/KTL (※8)
3
CSA
4
GOST (※8)
5
NEPSI (※8)
7
Non-explosionproof
0
Sensor unit: Temp. class T1, separate transmitter only,
1
CA025 to CA080 (high temp. service model) only
Sensor unit: Temp. class T2, separate tr. only, CA003 to CA080 only
2
Sensor unit: Temp. class T3, separate transmitter only
3
Sensor unit: Temp. class T4
4
Sensor unit: Temp. class T5, (-200℃ to +50℃),CA025 to CA080 (Low temp. explosionproof service) only
5
Description
Output 2: Mass flow
Output 2: Density
Output 2: Temperature
Output 2: Volume flow (true density)
Output 2: Volume flow (fixed density)
Output 2: Temperature
Output 2: Dens (true density)
Output 2: Density
Output 2: temperature
Output 2: Temperature
In the case of FOUNDATION fieldbus,PROFIBUS communication
Output 2: Mass flow
Output2: Volume flow (true density)
Output2: Volume flow (fixed density)
Output 2: Vol. flow (true dens.)
Output 2: Vol. flow (fixed dens.)
Output 2: Mass flow
Output 2: Mass flow
In the case of FOUNDATION fieldbus,PROFIBUS communication
In the case of FOUNDATION fieldbus,PROFIBUS communication
Selector Chart
○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ × × ○
× × ○ ○ ○ × × ×
○ ○ ○ ○ ○ × × ×
× × × × × ○ ○ ×
× × × × ○ × × ○
○ ○ ○ ○ ○ ○ ○ ○
× × × ○ × × × ×
○ ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ × ○ ○
× ○ ○ ○ ○ × ○ ○
○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ × × × ×
× ○ ○ ○ ○ × × ×
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× ○ ○ ○ ○ ○ ○ ○
× × ○ ○ ○ × × ×
○ ○ ○ ○ ○ ○ ○ ○
Single pulse
Double pulse
HART protocol version7、Bell202
ITK version6
Profile version3.02
RS-485 Modbus protocol