Type S Physical Orientation - Oval ALTI mass CA00A Instructions Manual

Table of Contents

Advertisement

L -- 740 -- 28 -- E
CA00A and CA001
Installation on a bench or wall are acceptable. We recommend the following orientations:
Installation on a bench
NOTE: For wall mounting, secure the body with bolts, making use of sensor unit fitting holes.

6.2.2 Type S physical orientation

NOTE:
Please refer to Item-13 for EHEDG
Authentication Article.
(1) The flowmeter may be installed either
in a horizontal line or a vertical line.
(2) Where cleansing is required or where
air bubble entrapment is likely, we
suggest installation in a vertical run.
(3) If cable entry points upwards, take
necessary measures to prevent rain
and water from entering the meter.
(4) Transmitter installation is correct if its display face is not in the horizontal plane.
View from side
(5) For the orientation of separately mounted transmitter, see 6.9 Separately Mounted Transmitter
Installation.
0
Installation on a wall
Fig. 6.3
Horizontal line
IN
View from bottom
Fig. 6.5
4-φ9 Fitting hole
(Fits M8 bolt.)
Vertical line
OUT
Fig. 6.4
View from top
OUT
IN