15.3 Type B product codes

Item
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ ⑬ ⑭ ⑮ ⑯ ⑰ ⑱
Model
C B
0 0 6
0 1 0
0 1 5
Nominal size
0 2 5
0 4 0
0 5 0
Fluid category
L
Temp. category (※1)
1
Pressure category
Major parts material
Process connection
Transmitter construction (※2)
Power source
Analog output (※3, 4, 5)
Pulse output (※3, 4, 5)
Pulse output type (※3, 4, 5)
Communication interface
Explosionproof rating
Explosionproof temperature class
NOTES
※1:Explosionproof specification has restrictions on temperature class.
※2:If temperature of the fluid exceeds 80℃, only "Separately mounted" type is available for the transmitter construction.
※3:When FOUNDATION fieldbus, PROFIBUS is selected for communication interface,
    product code categories of analog output is "X" and pulse output is "X" (pulse output type:"0").
※4:When "Volume flow (fixed density)" is selected for analog output or pulse output, fixed density will be applied.
※5:Simultaneous output of both "Volume flow (fixed density)" and "Volume flow (true density)" for analog output and pulse
output is not available.
※6:Communication interfaces "FOUNDATION fieldbus H1 communication" and "PROFIBUS PA communication" are
unavailable. (in preparation)
The new product code has been implemented since April 2017.
※:
Therefore, the product code explanation of the old product code will not be updated after April 2017.
Contact OVAL for any inquiries about the old product code.
Product Code
1
S
B
C
D
E
H
J
K
T
L
M
Z
1
2
1
2
A
B
C
D
E
F
G
H
J
K
X
A
B
C
D
E
F
G
H
J
K
X
0
1
2
1
2
3
4
0
1
2
3
4
5
7
ALTImass Type B
10mm connection (3/8")
15mm connection (1/2")
15mm connection (1/2")
25mm connection (1")
40mm connection (1・1/2")
50mm connection (2")
Liquid service
Standard (below 125° C)
Standard
SUS316L
Ferrule
JIS 10K
JIS 20K
JIS 30K
ASME 150
ASME 300
ASME 600
ASME 900
JPI 150
JPI 300
Other than above
Integrally mounted
Separately mounted
20 to 30VDC
85 to 264VAC (Safety rated 100 to 240VAC) , 50/60Hz
Output 1: Mass flow
Output 2 : Mass flow
Output 1: Mass flow
Output 2 : Density
Output 1: Mass flow
Output 2 : Temperature
Output 1: Mass flow
Output 2 : Volume flow (true density)
Output 1: Mass flow
Output 2 : Volume flow (fixed density)
Output 1: Density
Output 2 : Temperature
Output 1: Volume flow (true density)
Output 1: Volume flow (fixed density)
Output 1: Volume flow (true density)
Output 1: Volume flow (fixed density)
Non-output
In the case of FOUNDATION fieldbus,PROFIBUS communication
Output 1: Mass flow
Output 1: Volume flow (true density)
Output 1: Volume flow (fixed density)
Output 1: Mass flow
Output 2 : Mass flow
Output 1: Mass flow
Output 2 : Volume flow (true density)
Output 1: Mass flow
Output 2 : Volume flow (fixed density)
Output 1: Vol. flow (true dens.)
Output 1: Vol. flow (fixed dens.) Output 2 : Vol. flow (fixed dens.)
Output 1: Volume flow (true density)
Output 1: Volume flow (fixed density)
Non-output
In the case of FOUNDATION fieldbus,PROFIBUS communication
Non-output
In the case of FOUNDATION fieldbus,PROFIBUS communication
Open drain pulse (standard)
Voltage pulse
HART communication
FOUNDATION fieldbus H1 communication (※3)
PROFIBUS PA communication (※3)
Modbus communication
Non-explosionproof
TIIS
ATEX, IECEx
KOSHA/KTL (※6)
CSA (※6)
GOST (※6)
NEPSI (※6)
0 Non-explosionproof
3 Sensor unit: Temp. class T3, separate transmitter only
4 Sensor unit: Temp. class T4
L -- 740 -- 28 -- E
Description
Output 2 : Density (true density)
Output 2 : Density
Output 2 : Temperature
Output 2 : Temperature
Output 2 : Vol. flow (true dens.)
Output 2 : Mass flow
Output 2 : Mass flow
HART protocol version7、Bell202
ITK version6
Profile version3.02
RS-485 Modbus protocol
Single pulse
Double pulse
1