XMT/RCV Mode

3-7
XMT/RCV Mode
Transmitting/Receiving Data to/from an External Device
Connecting External
Devices
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Start
Connect an external device
(FIT, etc.) to Voice Unit.
(Transferring)
Set the mode selector switch
to the XMT.
Select a transfer mode (baud
rate, etc.) with the MSG No.
increment/decrement switch.
Set up the Voice Unit to match
the transfer mode (baud rate,
etc.) of the external device.
Prepare the external device
to receive.
Push the ST/SP switch to start
transfer.
To interrupt a transfer operation
in progress, push the ST/SP
switch again.
End
Data (messages) in the Voice Unit memory is transferred to external devices
via the RS-232C port of the Unit. External storage devices include comput-
ers, PROM chips (via a PROM Writer), etc.
For details on how to connect an external device to the Voice Unit, refer to
1-3 Input/Output Device Connections .
When connecting to a computer, communication software must be developed
by the user.
Section 3-7
(Receiving)
Set the memory protect
switch to OFF.
Set the mode selector switch
to RCV.
Set a transfer mode (baud
rate, etc.) with the MSG no.
increment/decrement switch.
Setup the external device to
match the transfer mode (baud
rate, etc.) of the Voice Unit.
Push the SP/ST switch to pre-
pare the Voice Unit to receive.
Start transferring data from
the external device.
33