Error Codes
Errors in REC mode
Display
RUN
PLAY
REC
ERR
OVF
The RUN and ERR indicators are
lit. The other indicators are unlit.
RUN
PLAY
REC
ERR
OVF
The RUN and ERR indicators are
lit. The REC indicator is blinking at
0.5 second intervals. The LED dis-
play a message number.
Note
: lit,
Ç Ç
: blinking at high speed
Ç Ç
Errors in ON-LINE mode
Display
RUN
PLAY
REC
ERR
OVF
The RUN and ERR indicators are
lit. The other indicators are unlit.
Note
: lit,
: blinking at high speed
Ç Ç
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Possible Cause
A different recording time has been
specified (by the DIP switch on the
back panel).
The message memory has failed.
The memory protect switch is in the ON
position (this will be true if the error
indication is made when the mode
selector switch is operated or when the
ST/SP switch is pressed).
No recording time remains because the
message memory is filled with data.
Or all available messages (1 through
60) have been recorded (in this case
the recording time may not be 0).
An attempt has been made to record a
message under the message number to
which a message has already been
recorded (this error indication occurs
when the ST/SP switch is pressed).
: blinking at 0.5 s intervals,
Possible Cause
No message is recorded.
The message memory has failed.
: blinking at 0.5 s intervals,
Correction
Match the recording time of the
message data (recorded message) with
the recording time set by the DIP switch
on the back panel.
Either clear the error code in ERA
mode or rewrite message data in the
RCV mode.
Turn OFF the memory protect switch
and press the ST/SP switch to record
the message.
In this state no new messages can be
recorded. Erase in the ERA mode the
message assigned to a message
number for which a new message is to
be recorded.
Specify a message number for which
no message has been recorded and
press the ST/SP switch. Or erase ( in
the ERA mode) the message number
for which a message has been already
recorded.
: blinking at 0.2 s intervals
Correction
Check that the message is being
recorded in REC mode or written in
RCV mode.
Either erase erroneous messages in
ERA mode, or rewrite correct
messages in RCV mode.
: blinking at 0.2 s intervals