Sentence Mode Example Programs
Example 7: Level operation
64
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
The number of repetitions and repeat intervals are as follows:
Message no. 12
Number of repetitions
3 times
Repeat intervals
0.2 s
00100
11503
00101
03000
11107
03001
03001
11112
11503
00102
03002
11210
03003
03003
11112
11107
00103
Message no. 16 is played back while input 00100 is ON.
Message no. 33 is played back while input 00101 is ON.
Message no. 7
Continuously
0.5 s
In this program, if two or more
@MOV
inputs turn ON during the same
#0023
scan time, the output command
110
programmed first takes prece-
dence. For example when in-
puts 00100, 00101, and 00102
DIFU
turns ON during the same scan
11112
time, then Message no. 12 is
transferred first followed respec-
tively by Message no. 7 and
DIFU
Message no. 25.
03000
11503 is the output message
area FULL flag
03001
MOV
#005F
110
11107
DIFU
03002
03003
11503
MOV
#0105
110
11210
11100
Section 4-1
Message no. 25
5 times
1.0 s