Voice unit
Table of Contents

Advertisement

ON-LINE Mode
(Example) One-shot operation in sequential mode
Message no. 5
output command
(played back twice at
1 second intervals)
Message no. 3
output command
(played back once at
2 second intervals)
Stop command
(word n+1 bit 00)
Message no. 5
playback
Message no. 3
playback
Message output
in progress flag
(word n+5 bit 02)
PC Data TransferProgram
Data Transfer
Example
Data and I/O Refresh
Timing
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
2nd time
1st
time
1 s
When the Voice Unit is operated in ON-LINE mode, the following type of pro-
gram must be written for the PC:
Execution command
1. Number of repetitions and repeat intervals
2. Word n (n = 100 + 10 x unit no.)
3. Message output command bit
Data is transferred between the Voice Unit and PC when PC I/O data is re-
freshed.
Interrupted
1st
time
2 s
MOV
This command transfers to the Voice
Unit the number of repetitions and re-
1
peat intervals for the message to be
2
played back.
This command turns ON the message
3
output command bit.
Section 3-8