ON-LINE Mode
One-shot operation in sequential mode
Message area during playback
No. 3
Output message area
(FULL status)
1
No. 10
2
No. 1
3
No. 6
19
No. 2
20
No. 25
The new output command is not
accepted even if it turns ON.
One-shot operation in priority mode
Message area during
playback
No. 3
Output message area
(FULL status)
1
No. 5
2
No. 6
3
No. 7
19
No. 32
20
No. 35
Only the output command of
a message having a lower
message number than those
of the messages in the mes-
sage area is accepted.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Message no. 3 has
been played back.
Messages are stored in
the sequence in which
their output commands
have turned ON. If more
than one output com-
mand turns ON at the
same time, the message
having the lower number
is stored.
The output command of
message no. 2 turns ON.
Messages whose output
command have turned ON
are stored, beginning with
the message having the
lowest message number.
The output message area FULL flag turns ON in response to the output com-
mand during OUT refreshing when the number of messages stored in the
storage area reaches 20, and when the input data in the same I/O refresh
area is refreshed. During the next input refreshing, when the number of mes-
sages decreases to 19 or less, the flag turns OFF.
Message area during playback
No. 10
Output message area
1
No. 1
2
No. 6
3
No. 12
19
No. 25
20
Vacant
The new output command
is accepted if it turns ON.
Message area during
playback
No. 2
Output message area
(FULL status)
1
No. 3
2
No. 5
3
No. 6
19
No. 29
20
No. 32
Message No. 35 is
canceled.
Section 3-8
47