Nomenclature and Functions
Indicators
Indicator
RUN (green)
PLAY (green)
REC (red)
ERR (red)
OVF (red)
LED display modes
MSG No. (red)
4
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Indication
Lit if Unit is operating without error. Unlit when there is a PC
communication error.
Lit during message playback or message erasure.
Blinking (at 0.5 second intervals) indicates that REC or ERA mode is
ready to operate.
Blinking (at 0.2 second intervals) indicates that XMT (transmit) mode
is ready to operate.
Ç Ç
Blinking at high speed during message output.
Ç Ç
Lit during message input (recorded) or erasure.
Blinking (at 0.5 second intervals) indicates that REC or ERA mode is
ready to operate.
Blinking (at 0.2 second intervals) indicates that RCV (receive) mode
is ready to operate.
Ç Ç Ç Ç
Blinking at high speed during message transmission.
Lit when an error occurs (such as memory failure) (For details, refer
to 5-2 Troubleshooting .)
Blinking (at 0.2 second intervals) indicates that the battery supply
voltage is low or that the battery is not connected.
Lit when the input level exceeds 80% of the permissible value during
message recording. Lit also when message recording mode is ready
to operate.
Note
: lit,
0.2 s intervals,
Ç Ç
Indication
Blinking
Conditions
: blinking at 0.5 s intervals,
: blinking at high speed
Function
Displays the message number currently valid
when in ON LINE, PLAY, REC, and ERA
modes (ON LINE/REC: 01 through 60,
Lit
PLAY/ERA: 00 through 60)
Displays the current communication mode
such as the baud rate in XMT or RCV mode
etc. (left digit: 0 through 7, right digit: 0
through 5)
Displays the recording time remaining when
in TIME mode. (64/48/32 through 00 seconds
possible depending on recording time)
Section 1-1