Omron SYSMAC C200H-OV001 Operation Manual page 76

Voice unit
Table of Contents

Advertisement

Phrase Combination Mode Example Programs
68
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
00100
00101
03000
03001
The messages, for the above program, are issued as follows:
When input 00100 turns ON, the message "No. 2 Tank Needs Water" is
played back twice at 1.0 second intervals.
When input 00101 turns ON, the message "No. 3 Tank Has A Problem" is
played back continuously at 0.2 second intervals. This message takes prece-
dence over the other message.
To stop the continuous playback of a message turn ON the stop command.
This command transfers repetition (2
@MOV
times) and interval data (1.0 s) to the
#0102
Voice Unit (when input 00100 turns
120
ON).
This command sets Phrase no. 2 as
@MOV
the first phrase and Phrase no. 20 as
#0220
the second phrase (when input
121
00100 turns ON).
This command sets Phrase no. 35 as
@MOV
the third phrase and Phrase no. 00 as
#3500
the fourth and last (Phrase no. 00
122
signifies the last phrase) phrase (when
input 00100 turns ON).
DIFU
03000
This command transfers repetition
@MOV
(continuously) and interval data (0.2 s)
#102F
and the priority command to the Voice
120
Unit (when input 00101 turns ON).
This command sets Phrase no. 3 as
@MOV
the first phrase and Phrase no. 20 as
#0320
the second phrase (when input 00101
121
turns ON).
This command sets Phrase no. 13 as
@MOV
the third phrase and Phrase no. 42 as
#1342
the fourth phrase (when input 00101
122
turns ON).
This command sets Phrase no. 00 as
@MOV
the fifth and last (Phrase no. 00 signi-
#0000
fies the last phrase) phrase (when input
123
00101 turns ON). Note the specification
of sixth phrase, in this example 00, is
arbitrary if the preceding phrase is the
DIFU
last one.
03001
12014
This command issues the message
output command.
Section 4-2