Spray Pump, Agitation and Boom Control Switches

The spray pump (on/off), agitation (on/off) and boom
control (on/off) switches are located on the spray control
console (Fig. 18). The switch includes a light that should
be illuminated when the switch is in the ON position.
Testing
1. Remove console covers to gain access to switch that
is to be tested (see Console Assembly in the Service
and Repairs section of Chapter 7 -- Chassis).
2. Make sure ignition switch is off. Disconnect the wire
harness electrical connector from the switch.
3. The switch terminals are marked as shown in Figure
19. In the ON position, continuity should exist between
terminals 2 and 3 and also between terminals 5 and 6.
In the OFF position, continuity should exist between ter-
minals 1 and 2 and also between terminals 4 and 5.
4. To test switch light, apply 12 VDC to terminal 8 (+)
and ground terminal 7 (--). The light should illuminate.
5. Replace switch if necessary.
6. Connect the wire harness connector to the switch af-
ter testing.
7. Secure console covers to machine (see Console As-
sembly in the Service and Repairs section of Chapter 7