Toro Multi Pro 5800 Service Manual page 203

Hide thumbs Also See for Multi Pro 5800:
Table of Contents

Advertisement

Disassembly (Fig. 20)
IMPORTANT: Make sure to remove and neutralize
chemicals from spray components before disas-
sembly. Wear protective clothing, chemical resist-
ant gloves and eye protection during repair.
1. Park machine on a level surface, stop engine, en-
gage parking brake and remove key from the ignition
switch.
2. Remove agitation valve assembly from machine
(see Spray Control Assembly in this section).
3. Disassemble agitation valve assembly as needed
using Figure 20 as a guide. Discard all removed O--rings
and gaskets.
4. See Boom and Agitation Valve Motor Service in this
section for disassembly and assembly information of the
agitation valve motor.
Assembly (Fig. 20)
NOTE: Coat all O--rings with vegetable oil before instal-
lation to reduce the chance of damage during assembly.
1. Assemble agitation valve assembly using Figure 20
as a guide. Replace all removed O--rings.
2. Install agitation valve assembly on machine (see
Spray Control Assembly in this section).
3. Operate spray system and check for leaks. Repair all
leaks before returning the sprayer to service.
Multi Pro 5800
1
2
1. Agitation valve motor
2. LH boom motor
Page 6 - - 25
3
4
Figure 21
3. Center boom motor
4. RH boom motor
Spray System

Advertisement

Table of Contents
loading