Spray Control Assembly

RIGHT
FRONT
1. Spray pump
2. Gasket
3. Screw clamp
4. Boom manifold valve assembly
The spray control assembly includes the agitation valve
and boom manifold valves. If the machine is equipped
with a Pro Control XP Spray System, the spray control
assembly will include a flowmeter between the agitation
valve and boom manifold valves (Fig. 15). Additional
valves may be attached to the spray control if the ma-
chine has any optional kits installed (e.g. foam marker,
eductor).
Removal (Fig. 14)
IMPORTANT: Make sure to remove and neutralize
chemicals from spray components before disas-
sembly. Wear protective clothing, chemical resist-
ant gloves and eye protection during repair.
Spray System
5
8
10
9
NOTE: ARROWS SHOW FLUID
FLOW DIRECTION
Figure 14
5. Tube coupler
6. Agitation supply hose
7. Agitation valve assembly
Page 6 - - 20
4
3
9
8. Flange head screw (6 used)
9. Flange nut (6 used)
10. Mounting bracket
1. Park machine on a level surface, stop engine, en-
gage parking brake and remove key from the ignition
switch.
2. Label hoses for proper installation after repairs are
completed (Fig. 16). Loosen hose clamps and discon-
nect hoses from spray control assembly as needed.
3. Loosen screw clamp (item 3) that secures compo-
nents of spray control assembly.
2
7
Multi Pro 5800
6
1

Advertisement

Table of Contents
loading