Hour Meter - Toro Multi Pro 5800 Service Manual

Hide thumbs Also See for Multi Pro 5800:
Table of Contents

Advertisement

Hour Meter

The hour meter is located on the right side of the console
assembly (Fig. 8).
Testing
1. Remove RH console cover to gain access to hour
meter (see Console Assembly in the Service and Re-
pairs section of Chapter 7 -- Chassis).
2. Make sure ignition switch is off. Disconnect the wire
harness electrical connector from the terminals on the
hour meter.
3. Connect the positive (+) terminal of a 12 VDC source
to the positive (+) terminal of the hour meter.
4. Connect the negative (--) terminal of the voltage
source to the other terminal of the hour meter.
5. The hour meter should move 1/10 of an hour in six
(6) minutes.
6. Disconnect voltage source from the hour meter.
7. When testing is complete, connect wire harness to
the meter terminals.
8. Secure RH console cover to machine (see Console
Assembly in the Service and Repairs section of Chapter
7 -- Chassis).
Electrical System
2
1. Console assembly
QUARTZ
0 0 0 0 0
1/10 WHEEL: WHITE W/BLACK NUMBERS
HOUR WHEELS: BLACK W/WHITE NUMBERS
Page 5 - - 10
Figure 8
2. Hour meter
RUNNING: INDICATOR
WINDOW
1
--
10
HOURS
Figure 9
Multi Pro 5800
1

Advertisement

Table of Contents