Battery Storage

If the machine will be stored for more than 30 days:
1. Remove the battery and charge it fully (see Battery
Service).
2. Either store battery on a shelf or on the machine.
3. Leave cables disconnected if the battery is stored on
the machine.

Battery Care

1. Battery electrolyte level must be properly main-
tained. The top of the battery must be kept clean. lf the
machine is stored in a location where temperatures are
extremely high, the battery will discharge more rapidly
than if the machine is stored in a location where temper-
atures are cool.
WARNING
Wear safety goggles and rubber gloves when
working with electrolyte. Charge battery in a well
ventilated place so gasses produced while
charging can dissipate. Since the gases are ex-
plosive, keep open flames and electrical sparks
away from the battery; do not smoke. Nausea
may result if the gases are inhaled. Unplug char-
ger from electrical outlet before connecting or
disconnecting charger leads to or from battery
posts.
IMPORTANT: Do not remove battery fill caps while
cleaning.
2. Check battery condition weekly or after every 50
hours of operation. Keep terminals and entire battery
case clean because a dirty battery will discharge slowly.
A. Clean battery by washing entire case with a solu-
tion of baking soda and water. Rinse with clear water.
B. Coat battery posts and cable connectors with
Battery Terminal Protector (Toro Part No. 107--0392)
or petroleum jelly to prevent corrosion.
Electrical System
4. Store battery in a cool atmosphere to avoid quick de-
terioration of the battery charge.
5. To help prevent the battery from freezing, make sure
it is fully charged (see Battery Service).
3. Battery cables must be tight on terminals to provide
good electrical contact.
Connecting cables to the wrong post could re-
sult in personal injury and/or damage to the
electrical system.
4. If corrosion occurs at battery terminals, disconnect
cables. Always disconnect negative (--) cable first.
Clean clamps and terminals separately. Reconnect
cables with positive (+) cable first. Coat battery posts
and cable connectors with Battery Terminal Protector
(Toro Part No. 107--0392) or petroleum jelly to prevent
corrosion.
5. Check electrolyte level every 25 operating hours and
every 30 days if machine is in storage.
6. Maintain cell electrolyte level with distilled or demin-
eralized water. Do not fill cells above the fill line.