Traction Circuit Component Failure - Toro Multi Pro 5800 Service Manual

Hide thumbs Also See for Multi Pro 5800:
Table of Contents

Advertisement

Traction Circuit Component Failure

The traction circuit on Multi Pro 5800 machines is a
closed loop system that includes the piston (traction)
pump and two (2) rear wheel motors. If a component in
the traction circuit should fail, debris and contamination
from the failed component will circulate throughout the
traction circuit. This contamination can damage other
components in the circuit so it must be removed to pre-
vent additional component failure.
The recommended method of removing traction circuit
contamination would be to temporarily install the Toro
high flow hydraulic filter (see Special Tools in this chap-
ter) into the circuit. This filter should be used when con-
necting hydraulic test gauges in order to test traction
circuit components or after replacing a failed traction cir-
cuit component (e.g. traction (piston) pump or wheel
motor). The filter will ensure that contaminates are re-
moved from the closed loop and thus, do not cause addi-
tional component damage.
Once the Toro high flow hydraulic filter kit has been
placed in the circuit, raise and support the machine with
Multi Pro 5800
all wheels off the ground. Then, operate the traction cir-
cuit to allow oil flow throughout the circuit. The filter will
remove contamination from the traction circuit during
operation. Because the Toro high flow filter is bi--direc-
tional, the traction circuit can be operated in both the for-
ward and reverse direction. The filter should be
removed from the machine after contamination has
been removed from the traction circuit. See Filtering
Closed--Loop Traction Circuit in the Service and Repairs
section of this chapter for additional information on us-
ing the Toro high flow hydraulic filter.
The alternative to using the Toro high flow hydraulic filter
kit after a traction circuit component failure would be to
disassemble, drain and thoroughly clean all compo-
nents, tubes and hoses in the traction circuit. If any de-
bris remains in the traction circuit and the machine is
operated, the debris can cause additional circuit compo-
nent failure.
Page 4 - - 5
Hydraulic System

Advertisement

Table of Contents
loading

Table of Contents