Special Tools

Diagnostic Display
The Diagnostic Display (Fig. 1) can be connected to the
Ultra Sonic Boom wire harness communication connec-
tor to verify correct electrical functions of the Ultra Sonic
Boom System. Toro electronic controller (TEC) inputs
and outputs for the Ultra Sonic Boom System can be
checked using the Diagnostic Display.
Toro Part Number for Diagnostic Display: 85- -4750
Toro Part Number for Overlay (English): 119- -9432
IMPORTANT: The Diagnostic Display must not be
left connected to the machine. It is not designed to
withstand the environment of the machine's every
day use. When use of Diagnostic Display is com-
pleted, disconnect it from the machine and recon-
nect
loopback
connector
communication connector. Machine will not oper-
ate without loopback connector installed on wire
harness. Store Diagnostic Display in a dry, secure,
indoor location and not on machine.
Multi Pro 5800
to
wire
harness
Page 7.1 - - 3
Figure 1
Figure 2
Ultra Sonic Boom System (Rev. A)