Removal (Fig. 61)
1. Park machine on a level surface, stop engine, en-
gage parking brake and remove key from the ignition
switch.
CAUTION
Rotate steering wheel and depress traction ped-
al in both forward and reverse to relieve hydrau-
lic system pressure and to avoid injury from
pressurized hydraulic oil.
2. Operate all hydraulic controls to relieve hydraulic
system pressure.
3. Read the General Precautions for Removing and
Installing Hydraulic System Components at the begin-
ning of this section.
4. Remove the spray pump drive motor and pump con-
trol manifold assembly from machine and then separate
pump control manifold from motor (see Spray Pump
Drive Motor Removal in this section).
5. If hydraulic fittings are to be removed from manifold,
mark fitting orientation to allow correct assembly. Re-
move fittings from manifold and discard O--rings.
Installation (Fig. 61)
1. If fittings were removed from manifold, lubricate and
place new O--rings onto fittings. Install fittings into man-
ifold port openings using marks made during the remov-
al process to properly orientate fittings. Tighten fittings
(see Hydraulic Fitting Installation in the General Infor-
mation section of this chapter).
2. Assemble and secure spray pump drive motor to
pump control manifold and then install the motor and
manifold assembly to machine (see Spray Pump Drive
Motor Installation in this section).
3. Check fluid level in hydraulic oil reservoir and adjust
as required.
4. Operate machine and inspect for leaks.
Multi Pro 5800
2
1. Spray pump drive motor
Page 4 - - 79
1
Figure 62
2. Pump control manifold