NOTE: If suction tube in tank develops an air leak, spray
2
performance will diminish when tank level reaches the
leak.
Removal (Fig. 24)
IMPORTANT: Make sure to remove and neutralize
1
chemicals from tank and spray components before
disassembly. Wear protective clothing, chemical re-
sistant gloves and eye protection during repair.
1. Park machine on a level surface, stop engine, en-
gage parking brake and remove key from the ignition
switch.
Figure 25
2. Remove suction strainer from spray tank.
1. Suction hose
2. Strainer location
3. Raise tank lid and remove strainer basket to gain ac-
cess to suction tube inside spray tank.
4. Remove suction tube assembly from spray tank and
disassemble tube using Figure 8 as a guide. Discard all
removed O--rings and gaskets.
Assembly (Fig. 24)
NOTE: Coat all O--rings with vegetable oil before instal-
lation to reduce the chance of damage during assembly.
1. Assemble and install suction tube assembly using
Figure 24 as a guide. Replace all removed O--rings and
gaskets. Make sure that clearance exists between suc-
tion tube foot and bottom of tank after assembly.
2. Check spray tank for leaks. Repair all leaks before
returning the sprayer to service.