4. If boom manifold valve assembly is to be removed:
A. Label wire harness connectors at boom manifold
valve assembly for proper installation after repairs
are completed. Unplug harness connectors from
boom valve motors.
B. Remove pressure gauge tube from boom man-
ifold assembly.
C. Support boom manifold valve assembly to pre-
vent it from falling. Remove fasteners that secure
boom manifold valve assembly to mount bracket.
D. Remove boom manifold valve assembly from
machine. Locate and retrieve gasket (item 2).
5. If agitation valve assembly is to be removed:
A. Unplug machine wire harness connector from
agitation valve motor.
B. Support agitation valve assembly to prevent it
from falling. Remove fasteners that secure agitation
valve assembly to mount bracket.
C. Remove agitation valve assembly from machine.
Locate and discard gasket (item 2).
6. Remove additional spray control components as re-
quired using Figure 14 as a guide. Discard all removed
O--rings and gaskets.
Assembly (Fig. 14)
NOTE: Coat all O--rings with vegetable oil before instal-
lation to reduce the chance of damage during assembly.
1. Install spray control components using Figure 14 as
a guide. Replace all removed O--rings and gaskets.
2. Position removed motor assembly to mount bracket.
Install and finger tighten fasteners to attach motor as-
sembly to mount bracket.
3. Make sure that screw clamp (item 3) is positioned on
spray control assembly.
4. Position new gasket (item 2) between removed com-
ponents.
5. Fit screw clamp to flanges of manifolds. Tighten
screw clamp to secure assembly.
6. Tighten fasteners to secure spray control to mount
bracket.
Multi Pro 5800
7. Using labels placed during disassembly, install
hoses to correct locations on spray control assembly
(Fig. 16). Secure hoses with hose clamps.
8. If removed, install pressure gauge tube to boom
valve motor assembly.
9. Plug machine wire harness connectors to valve mo-
tor(s).
10.Operate spray system and check for leaks. Repair all
leaks before returning the sprayer to service.
3
1. Boom manifold valves
2. Flowmeter
6
1. RH boom hose
2. Center boom hose
3. LH boom hose
Page 6 - - 21
2
1
Figure 15
3. Agitation valve
1
4
5
Figure 16
4. Agitation supply hose
5. Agitation bypass hose
6. Main supply hose
Spray System
2
3

Advertisement

Table of Contents
loading

Table of Contents