Toro 41393TE Software Manual

Turf sprayer with excelarate spray system
Hide thumbs Also See for 41393TE:

Advertisement

Quick Links

Multi Pro
Spray System
Model No. 41393TE-Serial No. 400000000 and Up
Read this information carefully to learn how to operate and maintain your product properly and to avoid injury
and product damage. You are responsible for operating the product properly and safely.
Whenever you need service, genuine Toro parts, or additional information, contact an Authorized Service Dealer
or Toro Customer Service and have the model and serial numbers of your product ready.
Visit www.Toro.com for product safety and operation training materials, accessory information, help finding a
dealer, or to register your product.

Introduction

The Software Guide for the Multi Pro 5800-D and
5800-G Turf Sprayer with ExcelaRate Spray System
provides information for using sprayer system
information and control sprayer system functions.
Contents
Introduction ............................................................... 1
Setup ........................................................................ 1
Before Using the Sprayer.................................... 1
Product Overview ..................................................... 2
Controls ............................................................. 2
Operation .................................................................. 3
Before Operation ................................................... 3
Accessing the Main Menu Screen....................... 3
InfoCenter Main Sub Menus ............................... 4
Calibrating the Sprayer ..................................... 14
During Operation ................................................. 26
InfoCenter Spray Area Screens ........................ 26
InfoCenter Advisories ....................................... 28
InfoCenter Fault Codes..................................... 29
Maintenance ........................................................... 30
Service Screens ............................................... 30
Diagnostics Screens......................................... 31
About Screens .................................................. 32
© 2019-The Toro® Company
8111 Lyndale Avenue South
Bloomington, MN 55420
®
5800-D Turf Sprayer with ExcelaRate

Setup

Before Using the Sprayer

Preparing the Machine when
Spraying in the Application Rate
Mode
Register at www.Toro.com.
1.
Fill the sprayer tank and fresh water tank; refer
to filling the spray tank and filling the fresh-water
tank procedures in the Operator's Manual.
2.
Calibrate the sprayer system; refer to
the Sprayer (page
3.
Set the application rate value(s) and active
application rate for the sprayer job; refer to
Setting the Rate 1 or Rate 2 Value (page 5)
Setting the Active Rate (page
4.
As needed, configure the following optional
settings:
Set the boost percentage; refer to
Boost Percentage (page
If you are using the
enter the volume of chemical in the sprayer
tank; refer to
Setting the Tank Volume (page
6).
Set the low limit indicator and the low limit
volume value for the tank; refer to
Low Limit Indicator (page 6)
Low Limit Volume Value (page
Set the preset agitation value; refer to
the Preset Agitation Value (Application Rate
Mode Only) (page
Original Instructions (EN)
All Rights Reserved *3431-740* A
Printed in the USA
Form No. 3431-740 Rev A
Software Guide
Calibrating
14).
4).
Setting the
5).
LOW LIMIT INDICATOR
Setting the
and
Setting the
7).
Setting
7).
and
,

Advertisement

Table of Contents
loading

Summary of Contents for Toro 41393TE

  • Page 1: Table Of Contents

    You are responsible for operating the product properly and safely. Whenever you need service, genuine Toro parts, or additional information, contact an Authorized Service Dealer or Toro Customer Service and have the model and serial numbers of your product ready.
  • Page 2: Product Overview

    Preparing the Machine when Product Overview Spraying in the Manual Mode Controls Fill the sprayer tank and fresh water tank; refer to filling the spray tank and filling the fresh-water tank procedures in the Operator’s Manual. InfoCenter Home Screen As needed, configure the following optional When you start the machine, the home screen settings: appears, displaying the corresponding icons that...
  • Page 3: Operation

    Master-Section Indicator Rinse-System Indicator Optional Kit The master-section indicator displays when the master section switch is in the O position (Figure The rinse-system indicator displays when the rinse system is active (Figure Sprayer-Section Indicators The left, right, and/or center sprayer sections display Agitation Indicator when any of the sprayer-section switches are in the The agitation indicator displays when the agitation...
  • Page 4: Infocenter Main Sub Menus

    This screen displays and allows you to set the Active (application) Rate, Rate 1, Rate 2, and the Boost-rate percentage. Setting the Active Rate Use the active rates option to set the sprayer preset rate to either rate 1 or rate 2. Press button 1 or 2 to navigate to the ACTIVE option...
  • Page 5 Setting the Rate 1 or Rate 2 Value Boost is active only as long as you hold buttons 1 and 5, then returns the set rate when you no longer press Press button 1 or 2 to navigate to the 1 or RATE and hold the buttons.
  • Page 6 Settings Setting the Tank Volume Press button 1 or 2 to navigate to the To access the screen, press button TANK SETTINGS option (Figure 12). 2 on the screen to navigate to the VOLUME MAIN MENU Settings option (Figure 10). g191833 Figure 12 g192022...
  • Page 7 Setting the Low Limit Volume Value speed you intend to run the machine, adjust the preset agitation value until the sprayer system Press button 1 or 2 to navigate to the LOW LIMIT pressure is between 1.5 to 2.0 times the target volume option (Figure 14).
  • Page 8 Display Settings Press button 5 to save the setting, exit the UNITS screen, and return to the Settings screen (Figure Press button 1 or 2 to navigate to the DISPLAY 17). option (Figure 16). Setting the Display Language Press buttons 1 or 2 to navigate to the LANGUAGE option (Figure...
  • Page 9 Setting the Display Backlighting or Contrast Setting Protection for Menus Press buttons 1 or 2 to navigate to the Note: BACKLIGHT Refer to Changing PIN Settings—Assessing or the option (Figure 20). CONTRAST the PIN Settings Sub-menu (page 10) for related information.
  • Page 10 Changing PIN Settings—Assessing the PIN Settings Sub-menu Press buttons 1 or 2 on the screen to DISPLAY navigate to the option (Figure 23). PIN SETTINGS g034292 Figure 24 1. Digit 1 4. Digit 4 g034290 2. Digit 2 5. Enter PIN Figure 23 3.
  • Page 11 Changing PIN Settings—Changing the PIN Code Press buttons 1 or 2 to select the PIN CHANGE option (Figure 26). g034306 Figure 27 1. Digit 1 4. Digit 4 2. Digit 2 5. Enter PIN g034303 Figure 26 3. Digit 3 Press button 4 to select the entry At the enter new PIN screen, press buttons 1...
  • Page 12 At the conform screen, press buttons 1 through 4 Press button 4 to turn the audio indicator O to enter your new PIN code. When you complete (Figure 31). entering the PIN, press button 5 (Figure 29). g191889 Figure 31 Press button 5 to save the setting, exit the screen, and return to the screen...
  • Page 13 g191707 g224287 Figure 35 Figure 33 Press button 4 to reset the settings for the Press button 3 or button 4 to lower or raise the selected option (Figure 35). boom width value (Figure 33). Repeat steps for other options that you Press button 5 to save your settings and exit the want to reset (Figure...
  • Page 14: Calibrating The Sprayer

    Calibrating the Sprayer Application Rate Mode Note: To calibrate the sprayer for manual mode operation, refer to setting the section—bypass valves in the Operator’s Manual for the machine. Ensure that the sprayer tank is clean; refer to Cleaning the Sprayer System in the Operator’s Manual.
  • Page 15 Evaluating the Which Type of Flow Calibration Optional 1 boom calibration: Calibrate the left or center or right sprayer section if you typically to Perform spray with 1 sprayer section. Perform this optional Use the Sprayer Sections Table to help determine calibration after performing the 3-sprayer-section how you typically spray turf with the machine and calibration and 2-sprayer-section calibration.
  • Page 16 g192583 Figure 41 g192636 Figure 43 Press button 4 to select Flow calibration option 1. Sprayer-pump switch 3. Throttle (Figure 41). 2. Agitation switch Fill the sprayer tank half full—600 L or 150 US gallons of water (Figure 42). Move the throttle to the F position (Figure Note:...
  • Page 17 g192605 g192607 Figure 44 Figure 46 1. Section-bypass shutoff valve (closed position) Press button 2 to advance to the next step (Figure 44). Set the agitation switch to the O position and Set the sprayer mode switch to the manual set the throttle to the F position (Figure...
  • Page 18 g192867 g192945 Figure 48 Performing the Sprayer Section Catch Test Note: Ready the graduated catch container. Set the master section switch to the O position (Figure 47). Use the application-rate switch to adjust the sprayer system pressure to approximately 276 kPa (40 psi);...
  • Page 19 g192976 Figure 50 Note: The sprayer system automatically opens the section valve, the sprayer nozzles spray for the catch test period, and the sprayer system automatically shuts off the section valve. Catch the water from the sprayer nozzle until the sprayer flow shuts off (Figure 51).
  • Page 20 system pressure and proceed to the next step. • If the volume is too high, use the application-rate switch to lower the sprayer system pressure and proceed to the next step. Repeat steps through until the volume of fluid in the graduated catch container ± 7.4 ml (1/4 fl oz) of the Target Volume displayed on the InfoCenter screen.
  • Page 21 Note: If the calibration value is out of bounds You will set only the sprayer section (Figure 57), contact your authorized Toro switches (Figure 38) to the O position that you service dealer; otherwise, review the error identified for calibration in...
  • Page 22 Speed Calibration Preparing for the Speed Calibration Press buttons 1 or 2 on the CALIBRATION sub-menu to navigate to the option SPEED (Figure 60). g192423 Figure 62 Press button 2 to advance to the next step (Figure 61). Mark a starting line on a testing area of turf (Figure 63).
  • Page 23 Mark a finishing line on a testing area of turf (Figure 33). Press button 2 to move the next step (Figure 64). Enter the Use buttons 3 or 4 to change the entered-distance value the InfoCenter and press button 2 (Figure 65).
  • Page 24 Calibration screen. Note: If the calibration value is out of bounds (Figure 69), contact your authorized Toro service dealer; otherwise, review the error message and repeat the calibration steps in Preparing for the Speed Calibration (page Performing the Speed Calibration (page 23).
  • Page 25 Press button 4 to select calibration option Press button 4 to toggle O or O the test SPEED (Figure 70). speed simulation (Figure 72). Press buttons 1 or 2 to navigate to the Press button 5 to save your settings and exit the SPEED option (Figure...
  • Page 26: During Operation

    During Operation InfoCenter Spray Area Screens Use the area screens to get information about the following: • Area sprayed (acres, hectares, or 1000 ft • Volume sprayed (US gallon or liters) Using the Total Area Screen g193543 • Use the Total Area screen to track the total number of acres and gallons that you have sprayed across all areas since the total area and total area volume information was last reset.
  • Page 27 Press button 2 for the Total Area screen (Figure sub-area and sub-area volume information for 76). active and inactive sub-areas. Note: If the volume sprayed and area sprayed data for a selected sub-area is cleared, the sprayer system deducts that sub-area volume sprayed and area sprayed quantity from the total volume sprayed and total area sprayed data.
  • Page 28: Infocenter Advisories

    • button 3 to select the Sub-Area screen Press button 3 to change the active sub-area (Figure 77). to the next sub-area. Use the InfoCenter buttons (Figure 77) to • Press and release button 4 to change the perform the following actions: active sub-area to the previous sub-area.
  • Page 29: Infocenter Fault Codes

    Fault codes display on the InfoCenter screen when there is a problem with the electronic or computer systems. For example, if the fuse for the Toro electronic controller is open, the InfoCenter displays fault code 1. Refer to the fault code table for a list fault codes and recommended actions.
  • Page 30: Maintenance

    The main power relay is not supplying current. Charging system fault Alternator voltage is too high or too low. Software version incompatibility The software versions are Call your authorized Toro mismatched distributor. Starter timeout The starter was engaged too long. Taction pedal neutral switch The traction pedal switch does not match ground speed.
  • Page 31: Diagnostics Screens

    Diagnostics Screens To access the Diagnostics screen press buttons 1 or 2 on the Main Menu screen to navigate to the option (Figure 83); refer to DIAGNOSTICS Accessing the Main Menu Screen (page g192028 Figure 81 • The number of hours the key was in the O position.
  • Page 32: About Screens

    88). g192030 Figure 86 Press button 3 to select the entry FAULT VIEWER (Figure 86). Review the fault viewer for sprayer system generated faults (Figure 87). Note: If you see faults listed in the viewer, contact your authorized Toro dealer.
  • Page 33 g192034 Figure 89 Press buttons 1 or 2 to scroll the machine information screen, the TEC controller information screen, or the InfoCenter information screen (Figure 89). Press button 5 to exit the A screen, and BOUT return to the D screen (Figure 87).
  • Page 34 Notes:...
  • Page 35 Notes:...

This manual is also suitable for:

Multi pro 5800-gMulti pro 5800-d