Lift commands are part of a dedicated control word. Each command is assigned to a physical digital input terminal. All the
main commands are given from the DI on the standard regulation board (see table 7.1).
Similarly, lift digital outputs are configured to perform the most common functions needed to realize a standard application,
such as run and brake contactor control logic.
In AGy -L drives, commands are always coming from Lift Control Word. It is possible to issue the Run Fwd or Run Rev
commands from keypad, in order to simplify the startup procedure.
Frequency references are coming from the multi-speed selector, which is the required setting for most applications.
However, it is possible to use other sources for the frequency reference, such as analog inputs or Motopotentiometer.
Ramps are initialized to a standard set of jerks and acceleration/deceleration that should meet the requirements of most
low speed applications. It is possible, though not recommended, to disable the S-shape and use linear profiles (F.250 = 0).
In that case the jerk parameters will have no effect.

7.1 Command Logic

In the standard version, drive commands may come from several different sources (keypad, terminals, serial line etc.).
In the Lift version the parameter defining the source of the commands can only assume the following values:
P.000 Sel comandi src = "[0]CtrlWordOnly"
Command assignment
Drive command
Enable src
Run Fwd src
Run Rev src
Freq Sel 1 src
Freq Sel 2 src
Freq Sel 3 src
Freq Sel 4 src
Ramp Sel 1 src
Ramp Sel 2 src
Ext fault src
Alarm Reset
Bak pwr act src
Forced stop src
AGy -L

7 - Default lift configuration

Source parameter
Setting
I.000
[2] DI 1
I.001
[3] DI 2
I.002
[4] DI 3
I.003
[5] DI 4
I.004
[6] DI 5
I.005
[7] DI 6
I.006
[0] False
I.007
[25] Short Floor Flg
I.008
[0] False
I.009
[8] DI 7
I.010
[9] DI 8
I.011
[0] False
I.012
[0] False
Table 7.1 – Command assignment
Deafult setting
Terminal
22
23
24
25
7
6
5
4
IPA
Possible setting
[0] False
100
[1] True
[2] DI 1
[3] DI 2
[4] DI 3
[5] DI 4
[6] DI 5
[7] DI 6
[8] DI 7
[9] DI 8
[10] DI Exp 1
[11] DI Exp 2
[12] DI Exp 3
[13] DI Exp 4
[14] AND 1
[15] AND 2
[16] AND 3
[17] OR 1
[18] OR 2
[19] OR 3
[20] NOT 1
[21] NOT 2
[22] NOT 3
[23] NOT 4
[24] FrqSel match
[25] Short Floor flg
See list of I.000
101
See list of I.000
102
See list of I.000
103
See list of I.000
104
See list of I.000
105
See list of I.000
106
See list of I.000
107
See list of I.000
108
See list of I.000
109
See list of I.000
110
See list of I.000
111
See list of I.000
185