gefran SIEIDrive LIFT AGy -L Instruction Manual page 72

Lift vector ac drives
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 47
Enable
Safety contacts
K3M
Run Fwd src
Run Rev src
Freq Sel 1 src
Freq Sel 2 src
KB
Ext Fault src
Fault reset src
(*) Standard = Freq Sel 3 src
Emergency Operation = Bak
pwr act src (see Chapter 9)
Emergency Module (optional)
EXT +24V
KB
MW22U...
Enable
5
4
3
EXT 0V
2
1
250
Braking resistor
F1
3 Ph
AC
mains
Digital input connection with external supply
Ext fault src
Fault reset src
EXT +24Vdc
EXT 0V
(**) Remove Jumper
Fig.7.1 – Lift standard wiring and connection of Emergency Module MW22U (optional)
72
KB
Regulation Board
K2M
K1M
22
DI 1
23
DI 2
24
DI 3
25
DI 4
7
DI 5
(*)
6
DI 6
5
DI 7
4
DI 8
9
+24Vdc
8
COM-DI
10
0V24
11
EM
EM
C
D
C
D
BR1
K1M
L1
U1/L1
V1/L2
W1/L3
PE1
5
DI 7
4
DI 8
9
+24Vdc
8
COM-DI
(**)
10
0V24
11
DO 1
16
DO 2
17
34
COM-DO
NO
1
NC
DO 4
3
2
NO
18
NC
DO 3
20
19
EXP-ENC-AGy
Vcc
35
GND
36
A+
12
A-
13
B+
14
B-
15
Power Board
U2/T1
V2/T2
W2/T3
PE2
-
L01
Brake cont
Output contactor
Freq < Thr1
0V24
To regulation board
Term. 9 and 10
(+24V, 0V24)
(for HTL encoders only)
Drive OK
Brake cont
+5V (for TTL encoders only)
K2M
K3M
3 Ph
Motor
Brake
FR
K2M
K3M
FR(R)
L02
Digital
Encoder
+
AGy -L

Advertisement

Table of Contents
loading