7.5 Menù Display
Code Display
d.000 Output frequency
d.001 Frequency ref
d.002 Output current
d.003 Output voltage
d.004 DC link voltage
d.005 Power factor
d.006 Power [kW]
d.007 Output speed
d.008 Speed ref
d.050 Heatsink temp
d.051 Drive OL
d.052 Motor OL
d.053 Brake res OL
d.100 Dig inp status
d.101 Term inp status
d.102 Vir dig inp stat
d.120 Exp dig inp stat
d.121 Exp term inp
d.122 Vir exp dig inp
d.150 Dig out status
d.151 Drv dig out sta
d.152 Vir dig out sta
022
d.170 Exp dig out sta
d.171 Exp DrvDigOutSta Expansion digital outputs status, commanded by DO functions
d.172 Exp VirDigOutSta
d.200 An in 1 cnf mon
AGy -L
Description
Drive output frequency
Drive frequency reference
Drive output current (rms)
Drive output voltage (rms)
DC Bus drive voltage (DC)
Power factor
Inverter output power
Drive output speed
Drive speed reference (d.001)*(P.600)
Drive heatsink temperature (linear sensor measured)
Drive overload (100% = alarm threshold)
Motor overload (100% = alarm threshold)
Braking resistor overload (100%=alarm thr)
Digital inputs status acquired by the drive (terminal or virtual)
Digital inputs terminal status of the drive regulat. Board
Virtual digital inputs status from drive serial link or field bus card
Expansion digital inputs status (optional terminal or virtual)
Expansion digital inputs terminal status of the drive expansion board
Expansion virtual digital inputs status from drive serial link or field bus card
Digital outputs status on the terminals of the drive regulation board
(commanded by DO functions or virtual DO)
Digital outputs status, commanded by DO functions
Virtual digital outputs status, commanded via serial link or field bus card
Expansion digital outputs status on the terminals of the drive regulation board
(commanded by DO functions or virtual DO)
Expansion virtual digital outputs status
(commanded via serial link or field bus card)
Analog input 1 destination;
it shows the function associated to this analog input
[0] Null funct
[1] Rif freq 1
[2] Rif freq 2
[3] Fatt liv Bst
[4] Fatt liv OT
[5] FattLiv Vred
[6] Fatt liv DCB
[7] FattEst Ramp
[8] FattRif freq
[9] VelPI LimFac
[10] MltFrq ch 1
[11] MltFrq ch 2
Unit
Var.
IPA
Hz
0.01 001
Hz
0.01 002
A
0.1
003
V
1
004
V
1
005
0.01 006
kW
0.01 007
mm/s 1
008
mm/s 1
009
°C
1
010
%
0.1
011
%
0.1
012
%
0.1
013
014
015
016
017
018
019
020
021
023
024
025
026
81