gefran SIEIDrive LIFT AGy -L Instruction Manual page 235

Lift vector ac drives
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 47
LCD Display
P.280 BU configuration
Braking unit configuration
P.281 Brake res value
Ohmic value of braking resistor
P.282 Brake res power
Braking resistor power
P.283 Br res thermal K
Braking resistor thermal constant
P.300 DC braking level
DC braking level
P.301 DCB lev fac src
DC braking level factor source
P.321 Autocapture Ilim
Catch on flight current limit
P.322 Demagnetiz time
Demagnetization minimun time
P.323 Autocap f scan t
Frequency scanning time during Pick Up
P.324 Autocap V scan t
Voltage scanning time during Pick Up
P.340 Undervoltage thr
Undervoltage threshold
P.341 Max pwrloss time
Restart time from undervoltage
P.342 UV alarm storage
Enabling of undervoltage alarm storage
P.343 UV Trip Mode
Undervoltage tripping mode
P.360 OV prevention
Automatic PickUp enabling after Overvoltage
P.380 Autoreset attmps
Number of autoreset attempts
P.381 Autoreset clear
En. automatic reset of autorestart attempts
P.382 Autoreset delay
Autoreset time delay
P.383 Autores flt rly
Alarm relay contacts behaviour during autoreset
P.400 Ext fault mode
External fault detection mode
P.410 Ph Loss detec en
Phase Loss detection enabling
P.420 Volt reduc mode
Voltage reduction mode
P.421 V reduction fact
P.422 V fact mult src
Source of voltage reduction factor multiplier
P.440 Frequency thr 1
Frequency 1 level detection
P.441 Freq prog 1 hyst
Hysteresis amplitude related to P-420
P.442 Frequency thr 2
Frequency 2 level detection
P.443 Freq prog 2 hyst
Hysteresis amplitude related to P-422
P.460 Const speed tol
Tolerance at constant speed
P.461 Const speed dly
Ramp end signalling delay
P.480 Heatsnk temp lev
Heatsink temperature signalling level
P.481 Heatsnk temp hys
Hysteresis band related to P.480
P.500 Switching freq
Modulation frequency
AGy -L
PARAMETER
DESCRIPTION
PICK LIST
LCD Selection
Description
[0] BU disabled
BU disabled
[1] BU en OL dis
BU enabled & Overload disable
[2] BU en OL en
BU & Overload enabled
[0] Null
Null
[1] Analog inp 1
Analog input 1
[2] Analog inp 2
Analog input 2
[3] Analog inp 3
Analog input 3
[0] Disable
[1] Enable
[0] Disabled
Function disabled
[1] CoastThrough Kinetic energy recovering
[2] Emg stop
Emergency stop mode
[0] Disable
[1] Enable
[0] OFF
[1] ON
[0] Alm alw,No AR - Drive in alarm. Alarm always
active. Alarm autoreset is not
possible.
[1] Alm run,No AR - Drive in alarm. Alarm active
only with running motor. Alarm
autoreset is not possible.
[2] Alm alw, ARes
- Drive in alarm. Alarm always
active. Alarm autoreset is
possible.
[3] Alm run, ARes
- Drive in alarm. Alarm active
only with running motor. Alarm
autoreset is possible.
[0] Disable
[1] Enable
[0] Always
Always
[1] Steady state
Costant speed only
[0] Null
Null
[1] Analog inp 1
Analog input 1
[2] Analog inp 2
Analog input 2
[3] Analog inp 3
Analog input 3
[0] 1kHz
[1] 2kHz
[2] 3kHz
[3] 4kHz
[4] 6kHz
[5] 8kHz
[6] 10kHz
[7] 12kHz
[8] 14kHz
[9] 16kHz
[10] 18kHz
1
0
2
(*)
1
250
ohm
1
(*)
0.01
25
kW
0.01
(*)
1
250
sec
1
75
0
100 % of I nom
1
0
0
3
120
20
(*)
% of I nom
1
(*)
0.01
10
sec
0.01
1
0.1
25
sec
0.1
0.2
0.1
25
V
0.1
0
0
80 % of P.020
1
0
0
25
sec
0.1
1
0
1
0
0
2
0
0
1
0
0
255
10
0
250
min
1
5
0.1
50
sec
0.1
1
0
1
0
0
3
1
0
1
0
0
1
100
10
100 % of P.061
1
0
0
3
0.5
0
F.020
Hz
0.1
0.2
0
F.020
Hz
0.1
0
0
F.020
Hz
0.1
0.5
0
F.020
Hz
0.1
0
0
25
Hz
0.1
0.1
0
25
sec
0.1
70
10
110
°C
1
5
0
10
°C
1
(*)
0
(*)
IPA
445
446
447
448
449
450
456
457
458
459
462
463
464
491
465
466
467
468
469
470
492
471
472
473
474
475
476
477
478
479
480
481
482